13. Programmable Function Parameters
The optional remote control FAR Order No. 5179 00 00 offers the following functions:
– Setting the range (3–20 cm)
– Setting the turn-off delay (0–10 s)
– Activating or switching continuous operation for 3.5 min or 11 min.
– Switching off the valve
– Restoring basic settings
– Test mode for simulation without water
– Setting automatic safety switch-off (2–210 s)
– Activating automatic flushing
☞
Important!
Reflecting surfaces can influence the sensor. There is a risk of having permanent
reflections. The range must be reduced for installations on reflecting surfaces of
stainless steel washbasins. If this is not sufficient, an additional base/spacing ring is
available (see
14. Maintenance and Servicing
Depending on the quality of the water, the local conditions and the rules and regulations
applicable on site, the fitting must be maintained and serviced at regular intervals.
Perform maintenance on the following components:
• Aerators (see
• Filters (see
Chapter
• Non-return valves (see
14.1 Push up the cleaning clip (a) in front of the sensor.
☞
The fitting is in sleep mode.
14.2 Use suitable cleaning agents that are not harmful to the fittings in a proper manner and
rinse with water after use. High-pressure cleaners must not be used for cleaning.
15. Replacing an Aerator
15.1 Use an open-end spanner to unscrew and replace the aerator (a).