• About 8 s after the end of the detected movement, the solenoid valve opens up for
the flush duration.

12. Function

12.1 Using the urinal.
• Water flows shortly after the urinal has been used.
• Water flow stops automatically after a set flush duration.
The flush duration can be set within the range 4 – 15 s (see
After a total flush duration of 6 s there is a 2 s interruption in the flush process to
ensure an intact odour seal.

13. Adjustments

Preliminary adjustments
Sensitivity: high
Mode: normal
Flush duration: 4 s
Adjusting sensitivity
S1 on: Sensitivity high
S1 off: Sensitivity low
Setting the mode
S2 on: Immunity mode
S2 off: Normal mode
Setting the flush duration
S3 left: Flush duration 4 s
S3 right: Flush duration 15 s

14. Replacement Parts

Designation
1 Radar sensor . . . . . . . . . . . . . . . . . . .85-032.12.687
2 Siphon . . . . . . . . . . . . . . . . . . . . . . . .85-032.12.689
3 Solenoid valve 6 V DC . . . . . . . . . . . .85-032.01.375
4 Control unit . . . . . . . . . . . . . . . . . . . .85-032.12.686
5 Power supply . . . . . . . . . . . . . . . . . . .85-032.12.688