"Auto-flush" function
Caution!
When the "Auto flush" function is used, the flow of water must be ensured.
• The "Auto-flush" function ensures that forced flushing takes place to exchange the
water in the tap lines after 24 or 72 hours of non-use.
• The "Auto-flush" function can only be switched on with the optional remote control
(FAR Order No. 2000101087).
• This function is switched off at the factory.

12. Controlling the Temperature

Sink mixer
with mixing lever
12.1 Set the mixing lever (a) in the desired position.
Sink mixer
12.2 Remove the plug (b).
12.3 Use an Allen key (c) to set the required mixed-water temperature.
12.4 Push in the plug.

13. Programmable Function Parameters

The optional remote control FAR Order No. 2000101087 offers the following
functions:
– Range can be set (3-20 cm)
– Turn-off delay can be set (0-10 s)
– Continuous flow can be switched to 3.5 min or 11 min.
– Switching off the fitting
– Basic settings can be restored
– Test mode for simulation without water
– Setting automatic safety switch-off (2–210 s)
– Automatic flushing can be activated
Important!
Reflecting surfaces can influence the sensor. There is a risk of having permanent
reflections. The range must be reduced for installations on reflecting surfaces such
as stainless steel washbasins. If this is not sufficient, an additional base/spacing ring
is available (see
with concealed mixing facility
Chapter
21.).