Important!
Observe the range settings when installing on a stainless steel washbasin
☞
The corner valves (c) must be provided by the customer.
10.2 Insert the grit filter (d) in the corner valve.
10.3 Screw the connector piece (e) together with the non-return valve on to the corner valve.
10.4 Place the connector hose (g) with the seal (f) on to the connector piece.
10.5 Insert the plug-in power supply into the socket.
10.6 Connect the line between the fitting and the power supply.
11. Function
11.1 Allow your hand to approach the sensor.
• Water flows.
11.2 Remove your hand from the sensor.
• Water flow stops automatically after a set flow time.
☞
The range of the sensor and the flow duration can be adjusted with the optional remote
control (FAR Order No. 5179 0000).
☞
Important!
Reflecting surfaces can influence the sensor. There is a risk of having permanent
reflections (see
"Auto-flush" function
Important!
When the "Auto flush" function is used, a proper flow of water must be ensured.
• The "Auto-flush" function ensures that forced flushing takes place to exchange the
water in the tap lines after 24 or 72 hours of non-use.
• The "Auto-flush" function can only be switched on with the optional remote control
(FAR Order No. 5179 0000).
• This function is switched off at the factory.
12. Controlling the Temperature
Sink mixer
with mixing lever
12.1 Set the mixing lever (a) in the desired position.
Sink mixer
with concealed mixing facility
12.2 Remove the plug (b).
12.3 Use a hollow hexagon wrench (c) to set the required mixing-water temperature.
12.4 Push in the plug.
Chapter 13.
for range adjustment).
Chapter
13.
7