18. Replacing the Solenoid Valve Cartridge
18.1 Close the corner valves.
18.2 Trigger the valve.
18.3 Loosen the screw (a) with a hollow hexagon wrench.
18.4 Pull the housing (b) from the base (c).
18.5 Loosen the screws (d).
18.6 Remove the mounting bracket (e).
18.7 Remove and replace the solenoid valve cartridge (f).
18.8 Reassemble in the reverse order.
19. Fault Correction
Fault
Water does not flow
Water flows
continuously
Water flow too weak
Water is too hot
Water is too cold
If you are unable to correct a fault or if the fault is not described in the fault correction
section, please inform our customer service department!
10
Cause
– Voltage supply interrupted
– Water flow regulator closed
– Grit filters are clogged with dirt
– Cleaning clip in front of the fitting
– Solenoid valve faulty
– Solenoid valve faulty
– Corner valves not fully opened
– Grit filters are clogged with dirt
– Aerator calcified
– Solenoid valve faulty
– Supply pressure too low
– Cold water is turned off
– Filters in the hot water part dirty
– Non-return valve faulty
– Hot water is turned off
– Filters in the cold water part dirty
– Non-return valve faulty
Remedy
➯ Restore it
➯ Open it
➯ Clean it
➯ Remove it
➯ Replace it
➯ Replace it
➯ Open it
➯ Clean it
➯ Replace it
➯ Replace it
➯ Check it
➯ Open it
➯ Replace them
➯ Replace it
➯ Open it
➯ Replace them
➯ Replace it