The effect of the safety valve must not be bypassed or made inoperative.
Contact between spraying device materials and hydrogen peroxide or other agents
that give off oxygen may result in increased pressure similar in nature to an explo-
sion. Never place such agents in the device.
Have damaged parts or parts that do not work properly repaired immediately by our
customer service department or by service partners authorized by us.
Avoid ignition sources in the environment if you spray combustible liquids.
Do not allow the device to remain under pressure and/or exposed directly to
sunlight. Make certain the device is not heated beyond the maximum operating
temperature
Never blow through the nozzles or valves with your mouth.
Use only MESTO spare and accessory parts.
We cannot assume any liability resulting from the use of third-party parts.
Wear suitable protective equipment when working with hazardous substances.
When pumping, always observe the pressure gauge to ensure the maximum spray-
ing pressure is not exceeded
the tank to dissipate completely
Scope of delivery
Tank [1], with pump [2] and spare parts pouch [3], spray line [4], instructions for use [5],
Technical data
Device family
Type
Total contents
Max. spraying pressure
Max. operating temperature
Weight when empty
Material of tank
Where device is carried
Technical residual quantity
Recoil force
Table 1
AUS
USA
.
FERROX PLUS
3565P
3585P
6 l
9 l
4.7 kg
5.2 kg
Steel with polyester coating
Shoulder
14
NZ
CDN
.
INOX PLUS
3595P
10 l
6 l
13 l
9 l
4.2 kg
Stainless steel
Back
Shoulder
0.03 l
0.78 l/min
< 5 N
IND
3615P
10 l
13 l
4.7 kg
Back