After usage
Observe the instructions in the section entitled "Safety".
1. Pull up the red button on the safety valve [12] until all excess pressure is released from
the tank. (
.
2. Lock the pump handle in place [13].
3. Unscrew the pump [2] from the tank [1].
Collect and dispose of the residual liquid according to all applicable laws, requirements
and regulations. Observe the instructions of the spray product manufacturer!
4. Empty and rinse the device with clear water.
5. Wipe off the device with a moist cloth.
6. For drying and storing the device, keep the tank and pump separate in a dry place pro-
tected from sunlight and freezing temperatures.
Clean the protective equipment and yourself every time after usage.
Care and maintenance
Observe the instructions in the section entitled "Safety".
After using the device 50 times or at least once a year:
Disassemble the pump [2] and grease the diaphragm [20].
Clean the nozzle [21] under running water. If required use a needle.
under running water.
Grease the O-rings [19] and [24]
Observe the legal requirements of your country for accident prevention and check
the device in regular intervals. If there are no special rules, we recommend you
have the device examined externally by a competent professional every 2 years
and subject it to an internal inspection every 5 years. We would be happy to provi-
de you with an inspection schedule in German or English.
Faults
pouch [3],
Fault
No pressure builds up
in the device
AUS
USA
.
.
Cause
The pump is not screwed on
tightly.
O-ring [19] on the pump is
faulty.
Diaphragm [20] is defective. Replace the diaphragm.
17
NZ
CDN
.
Remedy
Screw the pump on tightly.
Replace the O-ring.
IND
.
.
.

Publicité

loading

Ce manuel est également adapté pour:

Ferrox plus 3585pInox plus 3595pInox plus 3615p