Tabela 3: Níveis de emissão conduzida e radiada nas mecânicas E, F, G e H
Sem Filtro RFI Externo
Emissão
Modelo do
Conduzida
Inversor
Emissão
–Comprimento
(Com Filtro RFI
Radiada
Máximo do
Interno)
Cabo do Motor
Categoria C3 Categoria
CFW11 0142 T2
100 m (328.10 ft)
C3
(1)
CFW11 0180 T2
100 m (328.10 ft)
C3
(1)
CFW11 0211 T2
100 m (328.10 ft)
C3
(1)
CFW11 0105 T4
E
100 m (328.10 ft)
C3
(1)
CFW11 0142 T4
100 m (328.10 ft)
C3
(1)
CFW11 0180 T4
100 m (328.10 ft)
C3
(1)
CFW11 0211 T4
100 m (328.10 ft)
C3
(1)
CFW11 0242 T4
100 m (328.10 ft)
C3
(3)
CFW11 0312 T4
100 m (328.10 ft)
C3
(3)
F
CFW11 0370 T4
100 m (328.10 ft)
C3
(3)
CFW11 0477 T4
100 m (328.10 ft)
C3
(3)
CFW11 0515 T4
100 m (328.10 ft)
C3
(3)
CFW11 0601 T4
100 m (328.10 ft)
C3
(3)
G
CFW11 0720 T4
100 m (328.10 ft)
C3
(3)
CFW110760T4
100 m
C3
(3)
CFW110795T4
100 m
C4
(5)
CFW110877T4
100 m
C4
(5)
H
CFW111062T4
100 m
C4
(5)
CFW111141T4
100 m
C4
(5)
Notas da tabela 3:
(1) Para temperatura ambiente ao redor do inversor/filtro maior que 40 °C (104 °F) e corrente de
saída contínua maior que 172 Arms, é necessário utilizar filtro B84143B0250S020.
(2) Para temperatura ambiente ao redor do inversor/filtro de 40 °C (104 °F) e aplicações com
regime de sobrecarga pesada (HD, corrente de saída < 180 Arms), é possível utilizar o filtro
B84143B0180S020.
(3) Com núcleo toroidal nos três cabos de alimentação de rede (os três cabos conectados
a R/L1, S/L2 e T/L3 devem passar através de um único núcleo toroidal). Exemplo: TDK PN:
PC40U120x160x20 ferroxclube PN: U126x91x20-3F3. Se a instalação do inversor é feita dentro
do painel com atenuação de 10 dB na faixa de valores de frequência [30; 50] mHz) o núcleo
toroidal não é necessário.
(4) Frequência mínima de operação 2,5 Hz.
(5) Para maiores detalhes entrar em contato com a WEG.
Tabela 4: Níveis de emissão conduzida e radiada nas mecânicas D, E, F, G e
H- 500 a 690 Vca
Sem Filtro RFI Externo
Emissão
Conduzida -
Comprimento
Emissão
Máximo
Radiada
do Cabo do
Modelo do
Motor
Inversor
Categoria
Categoria C3
sem Painel
Metálico
CFW110002T6
25 m
C3
CFW110004T6
25 m
C3
CFW110007T6
25 m
C3
CFW110010T6
25 m
C3
CFW110012T6
25 m
C3
CFW110017T6
25 m
C3
CFW110022T6
25 m
C3
CFW110027T6
25 m
C3
CFW110032T6
25 m
C3
CFW110044T6
25 m
C3
CFW110053T6
100 m
C3
CFW110063T6
100 m
C3
CFW110080T6
100 m
C3
CFW110107T6
100 m
C3
CFW110125T6
100 m
C3
CFW110150T6
100 m
C3
CFW110170T6
50 m
C3
CFW110216T6
50 m
C3
CFW110289T6
50 m
C3
CFW110315T6
50 m
C3
CFW110365T6
50 m
C3
CFW110435T6
50 m
C3
CFW110472T6
50 m
C3
CFW110584T6
100 m
C4
(1)
CFW110625T6
100 m
C4
(1)
CFW110758T6
100 m
C4
(1)
CFW110804T6
100 m
C4
(1)
(1) Para maiores detalhes entrar em contato com a WEG.
Com Filtro RFI Externo
Emissão
Emissão
Conduzida –
Radiada
Referência Comercial
Comprimento
– Sem
do Filtro RFI Externo
Máximo do Cabo
Painel
(Fabricante: EPCOS)
do Motor
Metálico
Categoria C2
Categoria
B84143-B0150-S020
100 m (328.10 ft)
C2
B84143-B0180-S020
100 m (328.10 ft)
C2
(1)
B84143-B0250-S020
(2)
100 m (328.10 ft)
C2
B84143-B0150-S020
100 m (328.10 ft)
C2
B84143-B0150-S020
100 m (328.10 ft)
C2
B84143-B0180-S020
100 m (328.10 ft)
C2
(1)
B84143-B0250-S020
100 m (328.10 ft)
C2
(2)
B84143-B0250-S021
100 m (328.10 ft)
C3
(4)
B84143-B01420-S021 100 m (328.10 ft)
(4)
C3
B84143-B0400-S021
100 m (328.10 ft)
(4)
C3
B84143-B0600-S021
100 m (328.10 ft)
(4)
C3
B84143-B0600-S021
100 m (328.10 ft)
C3
(4)
B84143-B0600-S021
100 m (328.10 ft)
C3
(4)
B84143-B1000-S021
100 m (328.10 ft)
C3
(4)
B84143-B1000-S020
50 m
(4)
C3
-
-
B84143-1000-S80
-
-
-
-
B84143-B1250-S80
-
-
Com Filtro RFI Externo
Emissão
Conduzida -
Comprimento
Máximo do
Cabo do Motor
Item do Filtro RFI
Externo
Categoria C2
75 m
-
C2
75 m
-
C2
B84143A25R21
75 m
-
C2
75 m
-
C2
75 m
-
C2
B84143A36R21
75 m
-
C2
75 m
-
C2
B84143A50R21
75 m
-
C2
75 m
-
C2
B84143A80R21
75 m
-
C2
50 m
C2
C1
50 m
C2
C1
50 m
C2
C1
B84143B180S081
50 m
C2
C1
50 m
C2
C1
50 m
C2
C1
25 m
-
C2
B84143B0250S21
25 m
-
C2
B84143B0320S21
25 m
-
C2
25 m
-
C2
B84143B0400S21
25 m
-
C2
25 m
-
C2
B84143B0600S21
25 m
-
C2
-
-
-
-
-
-
B84143B1000S81
-
-
-
-
-
-
INTERFACE HOMEM-MÁQUINA- HMI-CFW-11
Soft key esquerda:
função definida pelo
texto do display logo
acima.
1. Incrementa conteúdo
do parâmetro.
2. Aumenta velocidade.
3. Seleciona grupo
anterior da lista Grupo
de Parâmetro.
Controle do sentido de
rotação do motor.
Ativa quando:
P0223 = 2 ou 3 em LOC
e /ou
P0226 = 2 ou 3 em REM.
Seleciona modo LOCAL
ou REMOTO.
Ativa quando:
P0220 = 2 ou 3.
Acelera motor com tempo determinado pela rampa de aceleração até a velocidade
definida por P0122.
Mantém motor nesta velocidade enquanto pressionada.
Ao ser liberada desacelera motor com tempo determinado pela rampa de desaceleração,
até a sua parada.
Ativa quando todas as condições abaixo forem satisfeitas:
1. Gira/Para = Para.
2. Habilita Geral = Ativo.
3. P0225 = 1 em LOC e/ou P0228 = 1 em REM.
Figura 29: Teclas e funções da HMI
Indicação modo:
Indicação do
- LOC: modo local.
sentido de giro
- REM: modo remoto.
do motor.
Status do inversor:
- Run
- Ready
Run
LOC
- Config
1800
rpm
- Aajuste
1.0
A
- Última falha:
60.0
Hz
FXXX
- Último alarme:
12:35
AXXX
- etc.
Indicação da hora.
Função da soft
key esquerda.
Ajuste em:
P0197, P0198 e P0199.
Figura 30: Display da HMI e exemplos da função padrão de fábrica
(modo monitoração)
Figura 31: Localização da tampa de acesso à bateria
Guia de Instalação
Soft key direita: função
definida pelo texto no
display logo acima.
1. Decrementa conteúdo
do parâmetro.
2. Diminui velocidade.
3. Seleciona próximo
grupo da lista Grupo
de Parâmetro.
Acelera o motor com
tempo determinado pela
rampa de aceleração.
Ativa quando:
P0224 = 0 em LOC e/ou
P0227 = 0 em REM.
Desacelera o motor com
tempo determinado pela
rampa de desaceleração,
até sua parada.
Ativa quando:
P0224 = 0 em LOC e/ou
P0227 = 0 em REM.
Indicação da
velocidade do
motor em rpm.
Parâmetros de monitoração:
- Velocidade do motor em rpm.
- Corrente do motor em Amps.
- Frequência de saída em Hz
1800rpm
(default).
P0205, P0206 e P0207:
seleção dos parâmetros que
serão mostrados no modo
monitoração.
Menu
P0208 a P0212: unidade de
engenharia para indicação
de velocidade.
Função da soft key
direita.
Tampa
CFW-11 | 57