Table 3: Conducted and radiated emission levels for sizes E, F, G and H
Without External RFI Filter
Conducted
Inverter Model
Emission -
Radiated
(Built-in RFI
Maximum
Emission
Filter)
Motor Cable
Length
Category C3
Category
CFW11 0142 T2
100 m (328.10 ft)
C3
(1)
CFW11 0180 T2
100 m (328.10 ft)
C3
(1)
CFW11 0211 T2
100 m (328.10 ft)
C3
(1)
CFW11 0105 T4
100 m (328.10 ft)
C3
(1)
E
CFW11 0142 T4
100 m (328.10 ft)
C3
(1)
CFW11 0180 T4
100 m (328.10 ft)
C3
(1)
CFW11 0211 T4
100 m (328.10 ft)
C3
(1)
CFW11 0242 T4
100 m (328.10 ft)
C3
(3)
CFW11 0312 T4
100 m (328.10 ft)
C3
(3)
F
CFW11 0370 T4
100 m (328.10 ft)
C3
(3)
CFW11 0477 T4
100 m (328.10 ft)
C3
(3)
CFW11 0515 T4
100 m (328.10 ft)
C3
(3)
CFW11 0601 T4
100 m (328.10 ft)
C3
(3)
G
CFW11 0720 T4
100 m (328.10 ft)
C3
(3)
CFW110760T4
100 m
C3
(3)
CFW110795T4
100 m
C4
(5)
CFW110877T4
100 m
C4
(5)
H
CFW111062T4
100 m
C4
(5)
CFW111141T4
100 m
C4
(5)
Notes for table 3:
(1) For inverter/filter surrounding air temperature higher than 40 °C (104 °F) and continuous
output current higher than 172 Arms, it's required to use B84143B0250S020 filter.
(2) For inverter/filter surrounding air temperature of 40 °C (104 °F) and HD applications (heavy
duty cycle, output current < 180 Arms), it's possible to use B84143B0180S020 filter.
(3) With toroidal core in the three line power supply cables (the three cables connected to R/L1,
S/L2 and T/L3 must pass through a single toroidal core). Example: TDK PN: PC40U120x160x20
ironxclube PN: U126x91x20-3F3. If the installation of the inverter is done inside the panel with
attenuation of 10 dB in the frequency adjustable range [30; 50] mHz), the toroidal core is not
necessary.
(4) 2.5 Hz minimum operating frequency.
(5) For further details, contact WEG.
Table 4: Conducted and radiated emission levels for frame sizes D, E, F, G
and H- 500 to 690 Vca
Without External
RFI Filter
Inverter
Model
CFW110002T6
25 m
C3
CFW110004T6
25 m
C3
B84143A25R21
CFW110007T6
25 m
C3
CFW110010T6
25 m
C3
CFW110012T6
25 m
C3
B84143A36R21
CFW110017T6
25 m
C3
CFW110022T6
25 m
C3
B84143A50R21
CFW110027T6
25 m
C3
CFW110032T6
25 m
C3
B84143A80R21
CFW110044T6
25 m
C3
CFW110053T6
100 m
C3
CFW110063T6
100 m
C3
CFW110080T6
100 m
C3
B84143B180S081
CFW110107T6
100 m
C3
CFW110125T6
100 m
C3
CFW110150T6
100 m
C3
CFW110170T6
50 m
C3
B84143B0250S21
CFW110216T6
50 m
C3
CFW110289T6
50 m
C3
B84143B0320S21
CFW110315T6
50 m
C3
B84143B0400S21
CFW110365T6
50 m
C3
CFW110435T6
50 m
C3
B84143B0600S21
CFW110472T6
50 m
C3
CFW110584T6
100 m
C4
(1)
CFW110625T6
100 m
C4
(1)
B84143B1000S81
CFW110758T6
100 m
C4
(1)
CFW110804T6
100 m
C4
(1)
(1) For more details contact Weg.
With External RFI Filter
Radiated
Conducted
Emission
External RFI
Emission -
- Without
Filter Part Number -
Maximum Motor
Metallic
(Manufacturer:
Cable Length
Cabinet
EPCOS)
Category C2
Category
B84143-B0150-S020
100 m (328.10 ft)
C2
B84143-B0180-S020
(1)
100 m (328.10 ft)
C2
B84143-B0250-S020
100 m (328.10 ft)
C2
(2)
B84143-B0150-S020
100 m (328.10 ft)
C2
B84143-B0150-S020
100 m (328.10 ft)
C2
B84143-B0180-S020
(1)
100 m (328.10 ft)
C2
B84143-B0250-S020
100 m (328.10 ft)
C2
(2)
B84143-B0250-S021 100 m (328.10 ft)
(4)
C3
B84143-B01420-S021 100 m (328.10 ft)
C3
(4)
B84143-B0400-S021 100 m (328.10 ft)
(4)
C3
B84143-B0600-S021 100 m (328.10 ft)
C3
(4)
B84143-B0600-S021 100 m (328.10 ft)
(4)
C3
B84143-B0600-S021 100 m (328.10 ft)
C3
(4)
B84143-B1000-S021 100 m (328.10 ft)
(4)
C3
B84143-B1000-S020
50 m
C3
(4)
-
-
B84143-1000-S80
-
-
-
-
B84143-B1250-S80
-
-
With External RFI Filter
External
RFI Filter
Part Number
Category
C2
75 m
-
C2
75 m
-
C2
75 m
-
C2
75 m
-
C2
75 m
-
C2
75 m
-
C2
75 m
-
C2
75 m
-
C2
75 m
-
C2
75 m
-
C2
50 m
C2
C1
50 m
C2
C1
50 m
C2
C1
50 m
C2
C1
50 m
C2
C1
50 m
C2
C1
25 m
-
C2
25 m
-
C2
25 m
-
C2
25 m
-
C2
25 m
-
C2
25 m
-
C2
25 m
-
C2
-
-
-
-
-
-
-
-
-
-
-
-
INTEGRAL KEYPAD - HMI-CFW11
Left "Soft key": Function
defined by the text
directly above on the
display.
1. Increases the
parameter contents.
2. Increases the speed.
3. Selects the previous
group of the Parameter
Group list.
Controls the motor
speed direction.
Active when:
P0223 = 2 or 3 in LOC
and /or
P0226 = 2 or 3 in REM.
Selects between LOCAL
or REMOTE situation.
Active when:
P0220 = 2 or 3.
It accelerates the motor following the acceleration ramp up to the speed defined in P0122.
It keeps the motor at this speed as long as pressed.
When released it decelerates the motor following the deceleration ramp down to stop.
Active when all the conditions below are fulfilled:
1. Run/Stop = Stop.
2. General Enable = Active.
3. P0225 = 1 in LOC and/or P0228 = 1 in REM.
Figure 29: Keypad keys and functions
Loc./Rem. indication:
- LOC: Local situation.
Motor speed
- REM: Remote situation.
direction indication.
Inverter status:
- Run
- Ready
Run
LOC
- Config
1800
- Self-tuning
1.0
- Last fault:
60.0
FXXX
- Last alarm:
12:35
AXXX
- etc.
Clock settings via:
Left soft key
function.
P0197, P0198 and P0199.
Figure 30: Keypad display and factory default functions example
(monitoring mode)
Figure 31: Keypad battery cover to access battery
Installation Guide
Right "Soft key":
Function defined by the
text directly above on the
display.
1. Decreases the
parameter contents.
2. Decreases the speed.
3. Selects the next group
of the Parameter
Group list.
Accelerates the
motor following the
acceleration ramp.
Active when:
P0224 = 0 in LOC and/or
P0227 = 0 in REM.
Decelerates the motor
following the deceleration
ramp, down to stop.
Active when:
P0224 = 0 in LOC and/or
P0227 = 0 in REM.
Motor speed
indication in rpm.
Monitoring parameters:
- Motor speed in rpm.
- Motor current in Amps.
1800rpm
- Output frequency in Hz
rpm
(default).
A
P0205, P0206 and P0207:
selection of the parameters
Hz
that will be displayed in the
Menu
monitoring mode.
P0208 to P0212: engineering
unit for the speed indication.
Right soft key
function.
Cover
CFW-11 | 17