OPERATION

Cleaning, care and maintenance

and a night phase, which are repeated daily (Pro1) or on every
working day (Pro2).
Theses phases are factory-set as follows:
- 08:00 am - 10:00 pm: Comfort mode
- 10:00 pm - 08:00 am: Night mode
Note
When time program Pro2 is enabled, the heater operates
during weekends exclusively in night mode.
To adapt time programs Pro1 and Pro2 according to your needs,
proceed as follows:
In the configuration menu, use "+" and "–" to call up the re-
quired time program.
Press "OK".
The start time for comfort mode is displayed.
Use "+" and "–" to set the required start time.
Press "OK".
The end time for comfort mode is displayed.
Use "+" and "–" to set the required end time.
Press "OK" to save.
Time program Pro3
You can use time program Pro3 to specify up to 14 separate com-
fort phases which are repeated weekly.
To configure a comfort phase in time program Pro3, proceed as
follows:
In the configuration menu, use "+" and "–" to call up time
program Pro3.
Press "OK".
The display shows "3---".
Press "OK".
A day of the week or a group of days is displayed.
Use "+" and "–" to select the required day or group of days.
Press "OK".
The start time for comfort mode is displayed.
Use "+" and "–" to set the required start time.
Press "OK".
The end time for comfort mode is displayed.
Use "+" and "–" to set the required end time.
Press "OK".
Comfort phase "3-01" has been configured.
To configure a further comfort phase, use "+" and "–" in time
program Pro3 to select display "3---". Proceed as described
above.
Note
To reset the selected comfort phases, activate parame-
ter P4.
Please note that activating parameter P4 resets all
time programs (Pro1, Pro2, Pro3) to the factory set-
ting.
6.4.3 Parameters
You can call up the following parameters:
8
| CON Premium
Display
Description
P1
Room temperature offset
P2
Time format
P3
Temperature display units
P4
Reset the time programs (Pro1, Pro2, Pro3).
P5
Reset relative heating time
To change the value of a parameter, use "+" and "–" to call up the
relevant parameter. Press "OK".
As soon as the "Editable parameter" symbol appears, you can
change the parameter value with "+" and "–". Press "OK" to save
the selected value.
P1: Room temperature offset
Uneven temperature distribution in the room can result in a differ-
ence between displayed actual temperature I1 and the room tem-
perature you measure. To compensate for this difference, a room
temperature offset of ±5 °F (±3 °C) can be set via parameter P1.
Example: The heater indicates I1 = 70 °F (21.0 °C). You have mea-
sured a room temperature of 68 °F (20.0 °C). There is a difference
of 2 °F (1.0 °C).
To compensate for the difference, select an offset of P1 = -2.0
(-1.0).
P2: Time format
Parameter P2 allows you to specify whether the time is displayed
in 12 hour or 24 hour format.
P3: Temperature display units
Parameter P3 is used to specify whether the room temperature is
displayed in degrees Fahrenheit [°F] or Centigrade [°C].
P4: Reset time programs
Activating parameter P4 resets all time programs (Pro1, Pro2,
Pro3) to the factory setting.
P5: Reset relative heating time
Activating parameter P5 resets the counter for relative heating
time (I2).
7.
Cleaning, care and maintenance
The heater contains no user serviceable parts.
Material losses
- Never spray cleaning spray into the air slot.
- Ensure that no moisture can enter the heater.
- If a pale brownish discoloration appears on the heater cas-
ing, wipe it off as soon as possible with a damp cloth.
- Clean the heater when cold with ordinary cleaning products.
Avoid abrasive or corrosive cleaning products.
Options
±3 °C | ±5 °F
12 h | 24 h
°C | °F
on | off
on | off
www.stiebel-eltron-usa.com

Publicité

Table des Matières
loading

Table des Matières