5.3. Noise
Sound level according to ISO 11202: Below 70dB.
5.4. Vibrations
Hand-arm vibrations according to ISO 5349-1
5.5. Anticipated failures
Bursted air tube in unit:
• The unit must never be used without the front
cover being mounted.
• The air closing valve on /in connection with the
unit must always be closed when not in use.
• Air tube and fitting should be examined regular-
ly and exchanged in case of visible damages.
Breakdown of non-return valves for air and water:
• The unit must never be used without the cover
beeing mounted.
• Air and water closing valve on/in connection
with the unit must always be closed when the
unit is not in use.
• After use of the unit all chemical non-return
valves must be thorougly rinsed with clean
water. Follow instructions in paragraph 9.4.
• Non-return valves for air and water should be
examined minimum once a year by authorised
personel for defects.
Repair of unit:
• Do not attempt to repair a defect unit by your-
self. Always contact an authorised service
company.
• Block and mark any defect unit in order to
avoid unintended use - see paragraph below
regarding "Rest risk - Use of the unit"
• For safety reasons only use approved and
original spare parts.
5.6. Rest Risk
Use of unit:
• Never use the unit without prior instructions in
use of the unit and its safety instructions. The
instruction must be prepared by an educated/
instructed personel.
• Never use the unit without having read the
enclosed guide and safety instructions.
• Always close water and air supply after use.
Damaged unit:
• Never use the unit if leakages (air, water or
chemical) are observed.
• Never use the unit if it is not possible to operate
the closing valves and/or if it is not possible to
select required operation.
• Never use the unit if it has been dislodged for
its original place of mounting.
6. Installation
For safety reasons it is important to read all of the
enclosed information before installation of this equip-
ment. In addition, the legislation in force at the time of
purchase must always be considered in connection
with the installation and mounting of this equipment,
no matter the contents of this manual. If there are
matters of dispute please contact your dealer.
The pipeline must be rinsed through be-
fore the system is connected.
Remove cover before the unit is mount-
ed on the wall.
6.1. Directions for mounting
• The unit should be mounted in
frost-free rooms only.
• The unit can be mounted on a
wall or on a separate frame which
may be installed in production
areas and anchored to the floor.
• For mounting on walls, please
note the following:
The wall for mounting should be
either a stable brick wall or a wall
made of concrete.
• If the wall the unit is to be mounted
on is made of bricks or concrete,
the enclosed screws and rawl
plugs are usable to mount the
delivered bracket, otherwise you
have to make sure that the carry-
ing capacity of the wall is suffi-
cient.
• The wall bracket should be mount-
ed on the wall according to the
above description and the station
is hung on to the bracket.
• When mounted on the bracket
secure the unit in the top by two
screws through the designated
holes. The hose and User Pack
holders should be mounted after-
wards. (See installation drawing)
6.2. Transportation
For secure transportation of the unit, we recommend
always to ensure, that the unit can not slide or tip.
The unit might have to be secured with straps.
Transportation of the unit only in horisontal position:
The unit must not be placed on the front where you
find the operation panel. Neither can it be placed
on top or bottom where connections and outlets are
mounted.