Anticipated Failures; Rest Risk; Installation; Directions For Mounting - Nilfisk FOOD MA2CM Mode D'emploi

Table des Matières

Publicité

5.5. Anticipated failures

Bursted air tube in unit:
• The unit must never be used without the front
cover being mounted.
• The air closing valve on/in connection with the unit
must always be closed when not in use.
• Air tube and fitting should be examined regularly
and exchanged in case of visible damages.
Breakdown of non-return valves for air and water:
• The unit must never be used without the cover
beeing mounted.
• Air and water closing valve on/in connection with
the unit must always be closed when the unit is
not in use.
• After use of the unit all chemical non-return valves
must be thorougly rinsed with clean water. Follow
instructions in paragraph 9.2.
• Non-return valves for air and water should be
examined minimum once a year by authorised
personel for defects.
Repair of unit:
• Do not attempt to repair a defect unit by yourself.
Always contact an authorised service company.
• Block and mark any defect unit in order to avoid
unintended use - see paragraph below regarding
"Rest risk - Use of the unit"
• For safety reasons only use approved and original
spare parts.

5.6. Rest risk

Use of unit:
• Never use the unit without prior instructions in use
of the unit and its safety instructions. The instruc-
tion must be prepared by an educated/instructed
personel.
• Never use the unit without having read the en-
closed guide and safety instructions.
• Always close water and air supply after use.
Damaged unit:
• Never use the unit if leakages (air, water or chemi-
cal) are observed.
• Never use the unit if it is not possible to operate
the closing valves and/or if it is not possible to
select required operation.
• Never use the unit if it has been dislodged for its
original place of mounting.

6. Installation

For safety reasons it is important to read all of the
enclosed information before installation of this equip-
ment. In addition, the legislation in force at the time of
purchase must always be considered in connection
with the installation and mounting of this equipment,
no matter the contents of this manual.If there are mat-
ters of dispute please contact your dealer.
The pipe line must be rinsed through
before the system is connected.
Remove cover before the unit is mount-
ed on the wall.

6.1. Directions for mounting

• The unit should be mounted in frost-
free rooms only.
• The unit can be mounted on a wall
or on a separate frame which may
be installed in production areas and
anchored to the floor.
• For mounting on walls, please note
the following:
The wall for mounting should be either
a stable brick wall or a wall made of
concrete.
• The wall bracket should be mounted
on the wall according to the above
description and the station is hung on
to the bracket. When mounted on the
bracket secure the unit in the top by
two screws through the designated
holes. The hose and User Pack hold-
ers should be mounted afterwards.
(See Installation drawing).

6.2. Transportation

For secure transportation of the unit, we recommend
always to ensure, that the unit can not slide or tip.
The unit might have to be secured with straps.
Transportation of the unit only in horisontal position:
The unit must not be placed on the front where you
find the operation panel. Neither can it be placed
on top or bottom where connections and outlets are
mounted.
In case the unit is moved at a temperature of approx
or below 0°C (32°F), you must always make sure that
the the unit has been fully emptied for water. If this is
not the case, you may damage the unit.

6.3. Electrical Installation

6.3.1.

Power supply

Connection instruction is mounted on the cables.
The phase order is subordinated.
169

Publicité

Table des Matières
loading

Table des Matières