4 Technical specifications

Required power supply
Supply voltage
Current consumption
Max. cable length
Connection
Power supply
Max. total cable length Standard
2
Simco 5x 0,34 mm
&
M12 Male-Female cable
Type power supply
Input
Standard
Without IQ Easy platform
Remote on/off
Starting time
Output
Output voltage emitters
Current per emitter to earth
IQ Easy platform
Without IQ Easy platform
High voltage OK (HV OK)
Environment
Use
Ingress protection class
Temperature
Material speed
Operating distance
Local signalling
2-colour LED's
Remote functions
(with IQ Easy platform)
Remote functions
(without IQ Easy platform)
Remote on/off
PerformaxIQEasyPerformaxIQEasySpeed_UM_9752154110_NL_D_GB_FR_V1_5
21–27 V DC
Max. 0.5 A DC
2
30 m x 0.34 mm
M12 connector, 5-pin
24V DC ± 2%
3,125Ω
62,5m
100-240 V AC
Manager IQ Easy
100-200 V AC
Extension IQ Easy
Simco Din-rail
Power supplies
Full control and readout via IQ Easy platform with an RS 485 serial
connection to standard voltage levels
10 – 30 V (Ri >10k)
30 ms
Max. 15 kV positive and negative
Max. 90 µA
RS485 voltage levels
Supply voltage -1 V, max. 50 mA
Industrial, internal use
IP66
0–55°C
Performax IQ Easy
Performax IQ Easy Speed
Performax IQ Easy
Performax IQ Easy Speed
Continuous
Green
In operation
Red
Overload
See Chapter 7 for all indications
The bar can be monitored and controlled using the
Manager IQ Easy (see also user manual Manager IQ Easy).
Switches high voltage on and off
24V DC ± 5%
24V DC ± 10%
2,25Ω
0,75Ω
45m
15m
Simco Desktop
Power supply
0 – 500 m/min
>500 m/min
100 - 500 mm
50 – 500 mm
Flashing
Standby
HV OK overload
GB
57

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Simco ion performax iq easy speed

Table des Matières