Table 3, faults when connected to a 24 V DC power supply
Signalling
LEDs on anti-static
bar do not light up
LEDs on anti-static
bar flashing green
LEDs on anti-static
bar light up red
LEDs on anti-static
bar light up green
LEDs on anti-static
bar flashing red (1
Hz)
LED on anti-static bar
flashes red (5 Hz)
PerformaxIQEasyPerformaxIQEasySpeed_UM_9752154110_NL_D_GB_FR_V1_5
Problem
No high voltage at
emitters
No high voltage at
emitters
Anti-static bar
overloaded
No/poor ionisation,
despite high voltage
at the emitters
High voltage at the
emitters, no HV OK
signal
No communication
with IQ Easy
platform
Cause
No supply voltage
Wiring fault
No remote on/off signal
Wiring fault
Anti-static bar fouled
Anti-static bar fitted
too close to conductive
machine parts
Anti-static bar fouled
Emitters are damaged
Anti-static bar incorrectly
positioned
Emitters are covered
HV OK overloaded
Wiring fault
During power up the
possibility of
communication is
checked
Solution
Switch on supply
voltage
Locate fault and
remedy, see 5.6
Connect/activate
remote on/off
Locate fault and
remedy, see 5.6.3
Clean anti-static bar
Move anti-static bar
Clean anti-static bar
Replace the anti-static
bar
Reposition the anti-
static bar, see 5.2
Remove the cover
Load HV OK differently
Locate fault and
remedy, see 5.6.3
Ignore during power up