Prior Check; Fitting The Anti-Static Bar - ITW SIMCO ION Performax IQ Easy Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

5.1 Prior check

- Check that the equipment is undamaged and that you have received the correct version.
- Check that the details on the packing slip correspond to the details of the product received.
If you have any problems and/or doubts, please contact Simco-Ion Netherlands or the agent in
your region.

5.2 Fitting the anti-static bar

Note:
- Conductive machine parts in the vicinity of the anti-static bar have a negative
influence on its operation.
- For optimum results, the anti-static bar must be fitted as per Figure 3.
- Fit the anti-static bar:
• Directly in front of the place where static electricity causes problems.
• At an optimum distance from the material to be neutralised:
o 100 - 500 mm (Performax IQ Easy)
o 50 - 500 mm (Performax IQ Easy Speed)
• With the emitters facing in the direction of the material to be neutralised.
Figure 3: Optimal position Performax IQ Easy and Performax IQ Easy Speed and optional Sensor IQ Easy bar