Functional Check; Functional Check Via The Leds (Connected To The Iq Easy Platform); Functional Check Via The Manager Iq Easy; Information Tab - ITW SIMCO ION Performax IQ Easy Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

7 Functional check

7.1 Functional check via the LEDs (connected to the IQ Easy platform)

The colour of the status LEDs on the anti-static bar indicates the status of the anti-static bar.
Table 1, overview status indication anti-static bar
Display
indication
Green
Blue
Orange
Red
Grey
* The high voltage can be on or off, depending whether the bar is/was active or on standby.

7.2 Functional check via the Manager IQ Easy

The display of the Manager IQ Easy displays information on the status of the anti-static bar.
On the main screen as well as on the device screens, the status of the bar can be viewed by
means of the background colour behind the icon
Green = standby, blue = running OK, orange = warning, red = alarm.
Detailed information is provided on the Information, Graphics, Action log and Data log Tab.

7.2.1 Information tab

With the
buttons you can scroll through the various pages.
Information regarding the operation to be found here:
- Ionisation Efficiency
covered, this value will drop. If the bar is set on standby, this value will be 0 %. The value
between the brackets will indicate the most recent value, e. g. 0 % (98 %).
- Ionisation current [uA]: both the negative and the positive ionisation current the bar provides
will be displayed here.
- Balance offset
- Last clean bar warning: indicates if and when the last warning has been issued that the
efficiency of the bar has dropped below the set clean bar warning level.
If a sensor bar is connected to the Performax IQ Easy bar, the display will also show:
- Web voltage [kV]: The current average (residual) charge measured of the active segments of
the sensor bar.
- Web voltage peak [kV]: The maximum measured average negative & positive (residual)
charge of the active segments of the sensor bar (during the last logfile refresh time). Every
time the logfile is written, this value will be reset to 0.

7.2.2 Graphics tab

The Graphics tab graphically shows the operation as function of the time.
- Yellow: the positive and negative ion current.
- Blue: the efficiency of the bar
If coupled with a sensor bar:
PerformaxIQEasyPerformaxIQEasySpeed_UM_9752154110_NL_D_GB_FR_V1_5
LED indication
Green flashing 1 Hz
Green on
Orange
Red on
Red flashing 5 Hz
xx%: indicates the effectiveness of the bar. Should the bar be dirty or
+40/60-
Status
Standby
In operation
Clean bar
High voltage overload
No communication (IQ)
:
High voltage
Off
On
On/Off*
On
On/Off*
70

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Simco ion performax iq easy speed

Table des Matières