ATTIX 130
- Troubleshooting
Fault
The exhauster fails to start
The rpm rate of the exhauster
increases
Dust leaks from the exhauster
Noisy suction motors
Electrostatic current on the
exhauster
- Manufacturer's assistance center
See appendix.
GB
C319
Causes
No power
Clogged primary filter
Clogged suction pipe
The filter is torn
Inadequate filter
Worn or broken carbons
Inexistent or inefficient
grounding
12
Remedies
Check whether power is reaching the
socket
Check whether the plug and cable are in
a good condition
Ask for assistance from an authorized
manifacturer's technician
Shake the filter. Replace it if this is not
sufficient
Check the suction pipe and clean it
Change it for another of identical cate-
gory
Change it for another of suitable category
and check
Demount and replace the motor
carbons
Check all ground con-nections. Particu-
larly check the suction inlet fitting; lastly,
the pipe must be strictly antistatic
07/2008