- Fit the filter into filtering chamber.
- Mount the head "D" and lock it in place with the closing
clips "C".
- Mount the lever "B" in position with the nut and relative
washer.
- Fit on the plug "A" by exercising a slight pressure.

- Replacing the Hepa filter

- Version for dust that is hazardous for the health: Class
H.
ATTENTION DANGER !
Take care not to raise the dust when this operation
is carried out. Wear a P3 mask and other protective
clothing plus protective gloves (DPI) suited to the
hazardous nature of the dust collected. Refer to
laws in force.
- Replacing the upstream Hepa filter (fig. 13)
- Remove the plug "A", unscrew the nut underneath and
remove the lever "B".
- Release the hooks "C" and lift the head "D".
- Unsrew the knob "G" and take the nut "F" under the
filter "E";
- Cover the filter "E" with a plastic bag and remove every-
thing;
- seal the bag, fit the new filter and hermetically close
the cover.
Mount the following parts in the given order:
- the absolute filter;
- nut and central knob for locking;
GB
- the head, locking it to the filtering chamber "C";
- the lever with the relative washer, nut and plug.

- Checking and cleaning the motor cooling fan

Periodically clean the motor(s) cooling fan to prevent the
electric motor(s) from overheating, particularly - if the
appliance is used in a dusty place.
C319

- Seal inspection

- Checking the condition of the hoses
Make sure that connecting hose hoses "A" is in a good
condition and correctly fixed.
If the hose is damaged, broken or badly connected to
the unions, this must be replaced.
When sticky materials are treated, check for possible
clogging along the hose, in outlet and on the baffle in
the filtering chamber.
Scrape outside the outlet and remove the deposited waste
as indicated in fig. 14.
- Checking the lid seal
If seal "A" under head "D" has become slack, unscrew
screws "B" that lock fastening latches "C" in place and allow
them to slide downwards until lid "D" closes perfectly.
Now tighten locking screws"B".
Replace seal "A" - fig. 15 - if an optimum seal cannot be
obtained.
- Checking the tightness of filter chamber
If seal "A" - fig. 16 - between the container and filter
chamber "C" fails to guarantee tightness:
- loosen the four screws "B" that lock filter chamber "C"
against vacuum structure.
- Allow filter chamber "C" to lower down and relock screws
"B" once it has reached the retention position.
The seal must be replaced if it is torn, cut, etc.
Replace seal "A" if the degree of tightness is still not
optimum.
- Cleaning and replacing the separator (fig. 17)
Note
If there is only a dust deposit on separator "D", allow the
dust to drop through the central hole.
Separator "D" should first be disassembled in order to
be perfectly cleaned:
- release lock fastening latches "A" and remove the head
"B";
- remove the filter;