ATTIX 145-01 / ATTIX 155-01
Problem
The vacuum cleaner suddenly stops
Dust leaks from the vacuum cleaner
Electrostatic current on the vacuum
cleaner
The vacuum cleaner does not start
after emptying the container
GB
C366

Troubleshooting

Cause
Clogged primary filter
Clogged vacuum hose
Circuit breaker activation
The filter is torn
Non existent or inefficient grounding
The level monitoring hose is clogged
12
Remedy
Shake the filter. Replace it if this is not
sufficient.
Check the vacuum hose and clean it.
Check the setting.
Check the motor electrical input.
Empty the container.
Contact an authorised after-sales
service centre if necessary.
Replace it with another of identical
type.
Check all ground connections.
Especially check the connection at the
inlet.
Release the container and clean the
level sensor.