6. CONNECTION TO POWER SUPPLY

The connection to the power source must be made
by trained and qualifi ed service technicians. The
power cable is supplied with the appliance. A ther-
momagnetic circuit breaker (fi eld supply) must be
installed between the socket and the power cable
of the appliance.
Prior to making the connection, make sure:
• The supply voltage corresponds to the appliance
voltage of 230 V / 50 Hz / 1 ph. Proper operation
of the appliance requires that the voltage should
be within ± 6% of the rated voltage.
• The electrical system used to power the appli-
ance must be suitable for rated parameters of
the appliance to be installed.

7. MAINTENANCE

Proper functioning and service life of the appliance
are essentially dependent on proper and routine
maintenance.
EN
Cleaning
Regular monthly cleaning of the appliance is rec-
ommended. Observe the following instructions.
Prior to cleaning, it is mandatory to unplug the
power cable of the appliance from the mains.
External cleaning of the counter top surface
Wash the appliance with a mild agent. Dry up using
a soft cloth.
Do not use abrasive and/or caustic products as they
may damage external surfaces of the appliance.
Internal cleaning
Clean the interior of the appliance at least once
a month, using an agent approved for food contact.
Do not use abrasive and/or caustic products as they
may damage internal surfaces of the appliance.
6
• The electronic system connected to the appliance
complies with applicable requirements. Electri-
cal connections and installation of the thermo-
magnetic circuit-breaker have been performed
by a qualifi ed person.
Connection stages:
• Install the thermomagnetic circuit breaker suit-
able for rated output power of the appliance to
be installed.
• Connect the appliance to the output on the ther-
momagnetic circuit breaker.
• Make sure the appliance is operational (signaled
by an indicator lamp).
Evaporator cleaning
In order to ensure good functioning of the appli-
ance, regular cleaning of the condenser about
every 4 months is recommended. Use a dry brush
or vacuum cleaner.