28
PSCA2 + PSF2 (PSC6000/PSC6001) cards – description
1*
L
N
8 8 8
1-
Terminals for powering the 230 V a.c. * board
2 -
Terminal clip for connecting internal lamp (already
connected)
3 -
Terminal clip for connecting the internal thermostat
(already connected)
4 -
Terminal clip for connecting anti-freeze heating element
(already connected
The minimum, double insulated, cable section, depends on the characteristics and dimensions of the system, and must
not be less than 2.5 mm². Before connecting up the device, cut off the mains power supply.
PS TOKEN -
PSF2 – managing auxiliary components
2
3
4
LAMPADA
TERMOSTATO RESISTENZA
1
2
1
2
1
2
1
2
3
4
Hardware and wiring
5
6
HELP
CITOFONO
1
2
3
4
5
6
5
6
7
8
9
10
5 -
Terminal clip for connecting HELP button
6-
Terminal clip for connecting a possible intercom
7-
Terminal clip for connecting automatic cash register to
other cash registers or parking facility components
8-
Already connected
7
A
B
GND
7
11
12
13 14

Publicité