10
PSR1 (PSE4000 – PSU4000) basic card – description
2
1
3
5
6
4*
1-
Terminals for connecting to transformer
2 -
5A token unit protection fuse
3-
Power source and 5A heating element protection fuse
4-
Terminals for powering * 230 V a.c. card
5-
Terminals for connecting power to internal heating unit
6-
Thermostat contact to monitor heating unit (see p. 45)
7-
24V a.c. output
8-
Token unit power source
9-
Motor command micro-switch
10- Terminals for connecting the devices that need to be
commanded (i.e. automations)
11- Token request button contact
The minimum, double insulated, cable section, depends on the characteristics and dimensions of the system, and must
not be less than 2.5 mm². Before connecting up the device, cut off the mains power supply.
PS TOKEN -
20
21
1
2
3 4 5
6
7
8 9 10
7
8
Hardware and wiring
19
9
10
11
12
12- Terminal for connecting the magnetic coil (only on token
enabled PSE4000 units)
13- Terminals for connecting sensors and keyboard
14- Terminals for connecting to the RBMP1 or to another
PSR1 or to a REM
15- Token present reader sensor connection
16- Connection to TSP00 sensors
17- Token quality control contact
18- Connectors for (R700 – R800) signal decoding cards
19- "Circuit On" warning LED light
20- DIP Switch selector
21- 1A circuit protection fuse
13
14
18
17
16
15