Connecting to the rear
1. Remove the top plate.
The top plate can be taken off the appliance
just like that.
2. At the outlet at the top, apply sealant to the
contact surface where the cover will be
positioned.
3. Install the cover using the materials.
4. At the rear, apply sealant to the contact surface
where the connection collar will be positioned.
5. Install the connection collar with the materials.
Preparing the outside air
connection
If the appliance is installed in a room without sufficient
ventilation, you can install the connecting kit on the
appliance for the outside air supply. Some of the air
inlets on the appliance must then be plugged with the
blanking material provided. We recommend applying a
connection set that has a valve you can close when
the stove is not in use.
The air supply tube is 100 mm in diameter. If the tube
is smooth, it may be no longer than 12 metres. If
accessories such as bends are used, the maximum
8
length (12 m) must be reduced by 1 m for each
accessory used.
1. Close the air inlet in the bottom plate with the
small cast-iron cover plates (1) and screws (2);
see following figure.
By closing the air inlet in the bottom plate you
prevent air being used for combustion from an
insufficiently ventilated space.
2. For connection to outside air via the floor:
a. Make an opening in the floor; see 'Appendix 2,
Measurements' for the correct position of the
opening.
b. Connect the foot hermetically to the floor using
a rubber seal.
c. Slide a straight air supply tube onto the
connection collar of the stove, so that it cannot
move; see following figure .
Subject to change because of technical improvements