Connecting to the rear
For a connection to the rear, the position of the con-
nection collar needs to be changed. The connection
collar is attached with 2 M8 nuts (key 13). Proceed as
follows:
1. First remove the baffle plate.
2. Unscrew the nuts and remove the connection col-
lar.
Check that the sealing tape on the contact sur-
face is not damaged. Replace the sealing tape
if it is damaged.
3. Place the connection collar turned 180° with
respect to its original position; see next figure.
Subject to change because of technical improvements
2
1
09-20021-015
4. Fit the connection collar with the 2 M8 nuts.
5. Replace the baffle plate.
Preparing the outside air
connection
If the appliance is installed in a room without sufficient
ventilation, you can install the connecting kit on the
appliance for the supply of outside air.
The air supply tube is 100 mm in diameter. If using a
smooth tube, it may be no longer than 12 metres long.
If accessories such as bends are used, the maximum
length (12 metres)) must be reduced by 1 metre for
each accessory used.
Outside air connection via the wall
1. Make an opening in the wall (see the appendix,
"Measurements", for the correct position of the
opening).
2. Close the air connection hermetically to the wall.

Installing and connecting

1. Position the stove in the correct place, and make
sure it is level. The appliance is fitted with
adjustable feet so that it can be levelled.
2
1
09-20021-016
11