Operation / Troubleshooting
If protector trips repeatedly, pump should be
removed and checked as to cause of difficulty.
Low voltage, long extension cords, clogged
impeller, very low head or lift, or a plugged or
frozen discharge pipe, etc., could cause cycling.
3. Pump will not remove all water. If operating
pump manually, and suddenly no water comes
out of the discharge hose, shut off the unit
immediately. The water level is probably very low
and the unit is no longer primed.
risk of electric shock. Before
attempting to check why unit has stopped
operating, disconnect power from unit.

TroubleshooTing CharT

SYMPTOM
Pump won't start or run.
Pump starts and stops
too often.
Pump won't shut off.
Pump operates but
delivers little or no water.
For parts or assistance, call Flotec Customer Service at
PROBABLE CAUSE(S)
Pump is not plugged in.
Blown fuse or tripped breaker.
Low line voltage.
Defective motor.
Defective float switch.
Impeller.
Float obstructed.
Backflow of water from piping.
Faulty float switch.
Defective float switch.
Restricted discharge
(obstacle or ice in piping).
Float obstructed.
Restricted intake screen.
Low line voltage.
Something caught in impeller.
Worn or defective parts or
plugged impeller.
Vent hole plugged.
Restricted intake screen.
Check valve is installed either
backward or upside down.
CORRECTIVE ACTION
Check and see if pump is plugged in to a proper outlet.
If blown, replace with fuse of proper size. If tripped, reset
breaker.
If voltage under recommended minimum, check size of wiring
from main switch on property. If OK, contact power company
or hydro authority.
Replace pump.
Replace float switch.
If impeller won't turn, remove lower pump body and locate
source of binding.
Remove obstruction.
Install or replace check-valve.
Replace float switch.
Replace float switch.
Remove pump and clean pump and piping.
Remove obstruction.
Remove the pump and clean the intake screen and the
impeller.
If voltage under recommended minimum, check size of wiring
from main switch on property. If OK, contact power company
or hydro authority.
Remove the pump and clean out the impeller.
Clean impeller if plugged; otherwise replace pump.
Use a nail or paperclip to open vent hole in discharge pipe.
Remove the pump and clean out the intake screen.
Be sure check valve is installed correctly.