Operation
risk of flooding. if the flexible
discharge hose is used, make sure pump is
secured in sump to prevent movement. failure
to secure pump may allow pump movement,
switch interference and prevent pump from
starting or stopping.
4. Power Supply: Pump is designed for 115 V.
60 Hz. operation and requires a minimum
15 amp individual branch circuit. Both pump and
switch are supplied with 3-wire cord sets with
grounding-type plugs. Switch plug is inserted
directly into outlet and pump plug inserts into
opposite end of switch plug.
pump should always be electrically
grounded to a suitable electrical ground such
as a grounded water pipe or a properly
grounded metallic raceway, or ground wire
system. Do not cut off round ground pin.
5. If pump discharge line is exposed to outside
sub-freezing atmosphere, portion of line exposed
must be installed so any water remaining in pipe
will drain to the outfall by gravity. Failure to do
this can cause water trapped in discharge to
freeze which could result in damage to pump.
Bracket
Pin
Float
Rod
notice: See instructions included with replacement switch, part number FPS17-66.
For parts or assistance, call Flotec Customer Service at
Vertical Switch Replacement
Switch
Housing
Bracket
Mounting
Screws
Rod Stop
6. After piping, check valve and float switch have
been installed, the unit is ready for operation.
7. Check pump operation by filling sump with water
and observing pump operation through one
complete cycle. For switch settings see Electrical
and Switch Specifications chart on Page 2.
failure to make this operational
check may lead to improper operation,
premature failure, and flooding.
operation
risk of electric shock. Do not handle a
pump or pump motor with wet hands or when
standing on wet or damp surface, or in water.
1. Shaft seal depends on water for lubrication. Do
not operate pump unless it is submerged in water
as seal may be damaged if allowed to run dry.
2. Motor is equipped with an automatic reset
thermal protector. If the temperature in the motor
should rise unduly, the switch will cut off all
power before damage can be done to the motor.
When motor has cooled sufficiently, the reset
switch will reset automatically and restart motor.
1
Mount the bracket on the switch
housing.
Slip the float and then the rod stop
2
onto the rod past the nib.
3 Insert the rod assembly up into the
switch housing and lock into place
with the pin.
NOTICE Be sure the pin holds the
rod in the switch housing or the pump
will not shut off.
4 Attach the switch to the discharge pipe
as shown. The bottom of the bracket should
be 7-1/4" above the top of the volute for
correct on/off points (see below).
7-1/4"