Troubleshooting - Flotec FP5100 Notice D'utilisation

Pompe centrifuge et inoxydable pour l'arrosage du gazon
Masquer les pouces Voir aussi pour FP5100:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Troubleshooting

Risk of electric shock. Can shock, burn or kill. To discharge capacitor, hold insulated handle screwdriver BY THE HANDLE and short
capacitor terminals together. Do not touch metal screwdriver blade or capacitor terminals. If in doubt, consult a qualified electrician.
Symptom
Possible Cause(s)
Motor will not run
Disconnect switch is off.
Fuse is blown or circuit breaker tripped
Starting switch is defective.
Wire ast motor are loose, disconnected, or wired
incorrectly.
Motor runs hot and
Motor is wired incorrectly
overload kicks off or
Voltage is too low.
motor does not run and
only hums.
Motor Runs but no water
Pump in new installation did not pick up prime
is delivered*
through:
1. Improper priming
2. Air leaks.
*(Note: Stop pump;
then check prime before
3. Leaking foot valve or check valve
looking for other causes.
4. Pipe size too small
Unscrew priming plug
Pump has lost prime through:
and see if water is in
priming hole).
1. Air leaks
2. Water level bellow suction pipe inlet.
Impeller is plugged
Check valve or foot valve is stuck shut
Pipes are frozen
Foot valve and/or strainer are buried in sand or mud
*Pump does not deliver
Water level in well is lower than estimated
water to full capacity.
Steel piping (if used) is corroded or limed, causing
excess friction
Piping is too small in size
Pump not being supplied with enough water
Pump leaks around
Clamp loose
clamp
FP5162 - 1HP
Discharge
Pressure
PSI (kPa)
5' (1.5)
10' (3)
10 (69)
55 (208)
49 (185)
15 (103)
51 (193)
46 (174)
20 (138)
45 (170)
42 (159)
25 (172)
38 (144)
35 (132)
30 (207)
31 (117)
28 (106)
35 (241)
23 (87)
19 (72)
40 (276)
17 (64)
13 (49)
45 (310)
50 (345)
All models except FP5182 and FP5182C have discharge and suction size of 1-1/2" NPT. FP5182 and FP5182C have 2" NPT suction and discharge.
For parts or assistance, call Flotec Customer Service at
Performance Chart in GPM(LPM)
FP5172 - 1 - 1/2 HP
Height of Pump Above Water in Feet (Meter)
15' (4.6)
20' (6.1)
5' (1.5)
10' (3)
48 (181)
45 (170)
67 (254)
61 (231)
45 (170)
44 (166)
66 (250)
58 (220)
39 (148)
37 (140)
61 (231)
56 (212)
32 (121)
29 (110)
55 (208)
52 (197)
24 (90)
20 (76)
48 (181)
45 (170)
16 (60)
11 (42)
39 (147)
37 (140)
8 (30)
33 (125)
27 (102)
18 (68)
14 (53)
Corrective Action
Be sure switch is on.
Replace fuse or reset breaker.
DISCONNECT POWER; Replace starting switch.
Refer to instructions on wiring. DISCONNECT POWER; check and tighten
all wiring.
Refer to instructions on wiring.
Check voltage being supplied to motor. Install heavier wiring if wire size is
too small (See Electrical / Wiring Chart)
In new installation:
1. Re-prime according to instructions.
2. Check all connections on suction line, with soapy water or shaving
cream
3. Replace foot valve or check valve.
4. Re-pipe using size of suction and discharge ports on pump.
In installation already in use:
1. Check all connections on suction line and shaft seal with soapy water.
2. Lower suction line into water and re-prime. If receding water level in
well exceeds 25' (7.6M), a deep well pump is needed.
Clean impeller
Replace check valve or foot valve
Thaw pipes. Bury pipes below frost line. Heat pit or pump house.
Raise foot valve and/or strainer above bottom of water source.
A deep well jet will be needed if your well is more than 25' (7.6M) dept to
water.
Replace with plastic pipe where possible, otherwise with new steel pipe.
Re-pipe using size of suction and discharge ports on pump
Add additional well points.
STOP PUMP, tighten clamp nut 1 - 2 turns. Alternately tighten and tap on
clamp with mallet to seat O-Ring. Do not overtighten.
15' (4.6)
20' (6.1)
5' (1.5)
56 (212)
46 (174)
69 (261)
55 (208)
45 (170)
65 (246)
54 (204)
44 (166)
59 (223)
51 (193)
43 (163)
52 (197)
44 (166)
37 (14)
47 (178)
34 (129)
28 (106)
42 (159)
20 (76)
11 (42)
34 (129)
8 (30)
25 (95)
14 (53)
800-365-6832
9
FP5182, FP5182C - 2HP
10' (3)
15' (4.6)
20' (6.1)
64 (242)
65 (246)
62 (235)
62 (235)
60 (227)
57 (215)
56 (212)
54 (204)
52 (197)
50 (189)
48 (181)
46 (174)
45 (170)
42 (159)
40 (151)
38 (144)
35 (132)
32 (121)
30 (113)
27 (102)
23 (87)
18 (68)
13 (49)
10 (38)
7 (26)

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Fp5162Fp5172Fp5182

Table des Matières