Troubleshooting

Capacitor voltage may be hazardous. To discharge capacitor, hold insulated handle screwdriver BY THE HANDLE and short capacitor
terminals together. Do not touch metal screwdriver blade or capacitor terminals. If in doubt, consult a qualified electrician.
SYMPTOM
POSSIBLE CAUSE(S)
Motor will not run.
Disconnect switch is off.
Fuse is blown or circuit breaker tripped
Starting switch is defective.
Wires at motor are loose,
disconnected, or wired incorrectly.
Motor runs hot and
Motor is wired incorrectly
overload kicks off or
Voltage is too low
motor does not run
and only hums.
Motor runs but no
Pump in new installation did
water is delivered*
not pick up prime through:
1. Improper priming.
2. Air leaks.
3. Leaking foot valve or check valve.
* (Note: Stop pump;
then check prime
4. Pipe size too small.
before looking for
Pump has lost prime through:
other causes.
1. Air leaks.
Unscrew priming
2. Water level below suction pipe inlet.
plug and see if water
is in priming hole).
Impeller is plugged.
Check valve or foot valve is stuck shut.
Pipes are frozen.
Foot valve and/or strainer are
buried in sand or mud.
*Pump does not
Water level in well is lower than
deliver water to full
estimated.
capacity.
Steel piping (if used) is corroded or
limed, causing excess friction.
Piping is too small in size.
Pump not being supplied with
enough water.
Pump leaks
Clamp loose.
around clamp.
FP5162 – 1 HP
Discharge
Pressure
PSI (kPa)
5' (1.5)
10' (3)
10 (69)
55 (208)
49 (185)
15 (103)
51 (193)
46 (174)
20 (138)
45 (170)
42 (159)
25 (172)
38 (144)
35 (132)
30 (207)
31 (117)
28 (106)
35 (241)
23 (87)
19 (72)
40 (276)
17 (64)
13 (49)
45 (310)
50 (345)
All models except FP5182 and FP5182C have discharge and suction size of 1 1/2" NPT. FP5182 and FP5182C have 2" NPT suction and discharge.
For parts or assistance, call Flotec Customer Service at
Performance Chart in GPM(LPM)
Height Of Pump Above Water in Feet (Meter)
15' (4.6)
20' (6.1)
5' (1.5)
48 (181)
45 (170)
67 (254)
45 (170)
44 (166)
66 (250)
39 (148)
37 (140)
61 (231)
32 (121)
29 (110)
55 (208)
24 (90)
20 (76)
48 (181)
16 (60)
11 (42)
39 (147)
8 (30)
33 (125)
18 (68)
CORRECTIVE ACTION
Be sure switch is on.
Replace fuse or reset circuit breaker.
DISCONNECT POWER; Replace starting switch.
Refer to instructions on wiring (Page 6). DISCONNECT POWER; check and
tighten all wiring.
Refer to instructions on wiring.
Check voltage being supplied to motor. Install heavier wiring if wire size is
too small (See Electrical / Wiring Chart).
In new installation:
1. Re prime according to instructions.
2. Check all connections on suction line, with soapy water or
shaving cream.
3. Replace foot valve or check valve.
4. Re pipe using size of suction and discharge ports on pump.
In installation already in use:
1. Check all connections on suction line and shaft seal with soapy water.
2. Lower suction line into water and re prime. If receding water level
in well exceeds 25' (7.6M), a deep well pump is needed.
Clean impeller.
Replace check valve or foot valve.
Thaw pipes. Bury pipes below frost line. Heat pit or pump house.
Raise foot valve and/or strainer above bottom of water source.
Clean foot valve and strainer.
A deep well jet will be needed if your well is more than 25' (7.6M)
depth to water.
Replace with plastic pipe where possible, otherwise with new steel pipe.
Re pipe using size of suction and discharge ports on pump.
Add additional well points.
STOP PUMP, tighten clamp nut 1 2 turns. Alternately tighten and tap on
clamp with mallet to seat O Ring. Do not overtighten.
FP5172 – 1-1/2 HP
10' (3)
15' (4.6)
20' (6.1)
61 (231)
56 (212)
46 (174)
58 (220)
55 (208)
45 (170)
56 (212)
54 (204)
44 (166)
52 (197)
51 (193)
43 (163)
45 (170)
44 (166)
37 (140)
37 (140)
34 (129)
28 (106)
27 (102)
20 (76)
11 (42)
14 (53)
8 (30)
1-800-365-6832
FP5182, FP5182C – 2 HP
5' (1.5)
10' (3)
15' (4.6)
69 (261)
64 (242)
65 (246)
65 (246)
62 (235)
60 (227)
59 (223)
56 (212)
54 (204)
52 (197)
50 (189)
48 (181)
47 (178)
45 (170)
42 (159)
42 (159)
38 (144)
35 (132)
34 (129)
30 (113)
27 (102)
25 (95)
18 (68)
13 (49)
14 (53)
7 (26)
9
20' (6.1)
62 (235)
57 (215)
52 (197)
46 (174)
40 (151)
32 (121)
23 (87)
10 (38)

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Fp5192-08Fp5162-08Fp5172-08Fp5182-08Fp5182-08c

Table des Matières