Algemeen
Digitale uitlezing
Het bedieningspaneel is uitgevoerd met een driedelig
LED-display die de lasstroom laat zien. During stand-
by the pre-set welding current is displayed, while the
mean current is shown during welding.
Disconnection error
A yellow LED indicates that the machine is
overheated due to overloading or because
mains voltage exceeds permissible range (195-
265V). When the situation is back to normal, the
machine will reconnect automatically. Therefore, weld-
ing cables are to be placed so as to avoid the risk of
unintended establishment of the arc when the
machine reconnnects.
Lasspanning
De aanwijzer lasspanning wordt verlicht om
veiligheidsredenen en om aan te geven of er spanning
staat op de stift van de TIG-toorts.
Welding current
Welding current is adjusted by means of
this button. The current is adjustable from 15 A to the
maximum current of the machine.
Function switch
This switch is used to choose between MMA or
TIG welding, between two-stroke and four-
stroke in TIG welding, and to choose ignition
method in TIG welding.
This symbol means MMA welding.
GEBRUIKSAANWIJZING
arc is established in the following way:
1) The torch is placed so that the Tungsten electrode
2) The torch trigger is activated, and the high voltage
The arc is established in the following way:
1) The torch is placed so that the Tungsten electrode
2) The torch trigger is activated, and the high voltage
is established in the following way:
1) The torch is placed so that the Tungsten electrode
2) The torch trigger must be kept pressed down.
36
This symbol means TIG welding.
Two-stroke
This symbol means contact-free striking. The
is quite close to the welding spot (1 or 2 mm).
generator of the machine will produce a voltage
impulse that ignites the arc. The welding process
has started. The welding process will stop when
the torch trigger is deactivated.
Four-stroke
This symbol means contact-free striking.
is quite close to the welding spot (1 or 2 mm).
generator of the machine will produce a voltage
impulse that ignites the arc. The torch trigger is de-
activated. The welding process will stop when the
torch trigger is reactivated. The arc will extinguish
after the period of slope-down time.
Two-stroke
This symbol means LIFTIG ignition. The arc
has contact with the welding spot.