Jumper Settings - Abus Profiline SG1800 Instructions D'installation

Masquer les pouces Voir aussi pour Profiline SG1800:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

6.2

Jumper settings

Setting
STROB
(Default: AUTO)
STROB
AUTO
STROB
M AN
TRIG
(Default: C+)
TRIG
C
TRIG
C -
TAMPER
(Default: EXT)
TAM PER
EXT
TAM PER
TAM PER
INT
14
Description
Defines the strobe operation mode.
AUTO: The strobe follows the sounder triggering.
MAN: The strobe follows the triggering of the ST
input.
Setting of the trigger potential of sounder.
C+: Use the C+ connection to activate the sounder
(Terminal C- is deactivated).
+
C-: Use the C- connection to activate the sounder
(Terminal C+ is deactivated).
Defines the tamper output operation (wall and cover
contact).
EXT: The NC tamper output is for connection to an
external tamper line.
1 PIN (no connection):
As for the EXT setting, the tamper output is for
connection to an external tamper line. However,
there is an internal series-connected 2K2 resistor for
the EOL connection.
INT:
Not used.

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Profiline sg1805Profiline sg1810

Table des Matières