13. CANopen object overview
Object
Name
Subindex
1000h Device type
1001h Error register
Pre-defined
1003h
error field
01-05h Standard error field
1005h Sync COB-ID
1008h Device name
1009h Hardware version
100Ah Software version
100Ch Guard time
100Dh Life time factor
1010h Store parameters
00h Biggest subindex
01h Save all parameters
1011h Restore default
parameters
00h Biggest subindex
01h All parameters
1014h Emergency COB-ID
1015h Inhibit time
emergency
1017h Producer heartbeat
time
1018h Identity object
00h Biggest subindex
01h VendorID
02h Product code
03h Revision number
04h Serial number
1029h Error behaviour
00h Biggest subindex
01h Communication
error
02h output error
1200h Server SDO
parameter
00h Biggest Subindex
01h COB-ID client→
server rec SDO
02h COB-ID Client→
client trans SDO
1800h Transmit PDO1
parameter
00h Biggest subindex
01h COB-ID
02h PDO type
03h PDO inhibit time
18
Format
Access Default
u32
ro
0001019Ah
u8
ro
u8
rw
032
ro
u32
ro
Visible string
Visible string
Visible string
u16
rw
u8
rw
ARR
u8
ro
u32
rw
ARR
u8
ro
u32
rw
u32
rw
80h+Node-ID
u16
rw
u16
rw
REC
ro
u8
ro
u32
ro
00000000h
u32
ro
00000000h
u32
ro
00000001h
u32
ro
xxxxxxxxh
ARR
u8
ro
u8
rw
u8
rw
ARR
u8
ro
u32
ro
600h+Node-ID
u32
ro
580h+Node-ID
REC
u8
ro
u32
rw
180h+Node-ID
u8
rw
u16
rw
Save
Description
DS410: Inclinometer
00h
Internal error acc. to DS301
00h
Number of elements in the error list
00h
Errors encountered
80h
Identifier of the sync object
KINAX N702-CANopen
1.0
Product hardware version
1.0
Product software version
200h
Timer for node guarding
03h
Multiplicator of guard time
01h
Numbers of option "save"
02h
In case of a modification all parameters are
automatically saved
01h
Numbers of option "restore"
01h
If this string is added on "load", the para-
meters are imposed with the factory default
settings
COB identifier of emergency objektes
0000h
Minimum distance between two emergency
declarations (in 100μs)
0000h
Producer heartbeat time in ms
4h
Number of entries
Vendor no. issued by CiA
157554 N702-CANopen
Number of product revision
Unique consecutive serial number
02h
Number of entries
00h
Behaviour when there is a communication
error
00h
Behaviour when there is a measuring error
02h
Number of entries
Identifier of default receiver SDO channel
Identifier of default transmit SDO channel
01h
Number of entries for transmit-PDO
Identifier of the 1st PDO's
FFH
01h-F0h: PDO will be transmitted after "n"
sync pulses
FEh: PDO is transmitted upon modification
FFh: PDO is transmitted after the event-
timer-time
0000h
Minimum distance of the PDOs at
transmission type = FEh (in 100μs)