Installing Frc Models; Electrical Information - Hatco 3CS Serie Manuel D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

English

Installing FRC Models

The FRC-I Model mounts into a countertop. Use the following
procedure to mount the unit to the countertop.
NOTE: FRC-II Models are shipped pre-assembled in a stand
from the factory.
BURN HAZARD: Drain water may reach temperatures in
excess of 200°F (93°C). Use appropriate plumbing materials
when installing drain.
Do not use extension pipes on the inlet and outlet
connections on water heater units. Poor performance or
unsafe conditions may occur.
1. Cut the countertop opening. Refer to the Countertop Cutout
figure in this section for more information.
a. Measure and mark the countertop for the cutout.
(19-7/8" [505 mm] x 11-7/8" [301 mm]).
• The corners need a 1" (25 mm) x 45° chamfer for the
5/16" (8 mm) mounting holes.
b. Cutout the countertop using the markings.
2. Drill the 5/16" (8 mm) mounting holes at each chamfer
corner. Refer to the Countertop Cutout figure in this section
for dimensions.
19-3/8"
(492 mm)
19-7/8"
(505 mm)
1" (25 mm)
45° chamfer
Mounting Hole
Top View of Countertop Cutout
NOTE: The dotted lines in the Countertop Cutout figure mark
the area to cut out.
3. Apply a bead of NSF-approved sealant between the
countertop material and the mounting flange on the unit. The
sealant must be rated for use at a minimum temperature of
250°F (121°C).
4. Place the unit into the countertop opening.
a. Align the studs on the bottom of the sink into the 5/16"
(8 mm) mounting holes at each chamfer corner.
b. Fasten with the included nylock nuts.
NOTE: There must be a minimum of 30" (762 mm) clearance
below the countertop to accommodate the tank, heater,
and drain assembly.
5. Remove any excess sealant.
Form No. 3CSFRM-0415
CAUTION
11-1/4"
11-7/8"
(286 mm)
(301 mm)
5/16" (8 mm)

Electrical Information

Hatco 3CS and FR Model Water Heaters are available for
operation on standard power systems. Check the specification
label for the proper power supply.
All internal electrical connections have been made at the
factory. Refer to the appropriate "Electrical Rating Chart" for
wiring and voltage requirements.
Turn OFF power switch, disconnect unit from power
source, and allow unit to cool before performing any
cleaning, adjustments, or maintenance.
Connect Water Heaters to the same power supply as
indicated on the specification decal only. Connecting units
to an incorrect power supply will void the product warranty
and may damage the equipment.
Hardwired Connections
Conductors from a properly sized fused disconnect switch or
circuit breaker must be wired to the heater in accordance with
local electrical codes.
1. Remove the bottom cover screws and remove the bottom
cover.
2. Locate the heater terminal block inside the unit.
NOTE: 3CS and FR Models rated for 6 and 9 kW (wired for
three phase open delta) can be field converted to single
phase. Refer to the electrical diagram supplied with unit
or contact Hatco for assistance.
3. Bring power leads from a properly sized disconnect switch
or circuit breaker through the knockouts provided on the
unit, and connect to the terminal block.
• Use copper wire only. Tighten connections properly to a
minimum of 40 inch pounds.
NOTE: Refer to "Dimensions" in the SPECIFICATION section
for knockout locations.
NOTE: Due to the rigors of transportation all connections should
be checked for tightness before heater is put into
operation.
4. A grounding lug is provided near the terminal block. An
equipment grounding conductor must be properly connected
to it.
5. Replace and secure bottom cover using previously removed
screws.
Cord, Plug, and Receptacle Connections
FR-3 and FR-4 water heaters may be supplied with an optional
electrical cord, plug, and receptacle. FR-3 Models use a NEMA
6-20R receptacle, FR-4 Models use a NEMA 6-30R receptacle.
All FRC Models are shipped with cords.
ELECTRIC SHOCK HAZARD: Units supplied with an
electrical cord, plug, and receptacle require installation of
receptacle to on-site electrical system. Connection must
be properly grounded and of correct voltage, size, and
configuration for electrical specifications of unit. Contact a
qualified electrician to determine and install proper
electrical connection.
13