revised 07/2017
BATTERY CHARGING
NOTE
Charge the batteries when there is only one flashing segment displayed in the battery symbol (51-C), or at the end of the
shift.
Keeping the batteries charged make their life last longer.
CAUTION!
When the batteries are discharged, charge them as soon as possible, as that condition makes their life shorter.
Check for battery charge at least once a week.
WARNING!
When using lead (WET) batteries, battery charging produces highly explosive hydrogen gas. Charge the
batteries in well-ventilated areas and away from naked flames.
Do not smoke while charging the batteries.
Keep the recovery tank raised until the battery charging cycle is over.
WARNING!
Pay close attention when charging WET CELL batteries, as there may be battery fluid leakages. The battery fluid
is corrosive. If it comes in contact with skin or eyes, rinse thoroughly with water and consult a physician.
1.
Drive the machine to the appointed recharging area.
2.
Ensure that the machine is off and the user key (52) has been removed.
3.
Lift the cover (34) and check that the recovery tank (33) is empty; if not, empty it using the drain hose (12).
4.
Close the cover (19).
5.
Grasp the handle (16) and carefully lift the tank (33).
6.
(For WET CELL batteries only) Check the level of electrolyte inside the batteries. If necessary, unscrew the caps and top up.
When the correct level is restored, close the caps and clean the tops of the batteries.
7.
Plug the battery charger (6) into the mains electricity supply (the mains voltage and frequency must be compatible with the
battery charger values shown on the machine serial number plate).
NOTE
When the battery charger is connected to the electrical mains, all machine functions are automatically cut off.
When the first or second segment from the left in the battery symbol (51-L) is flashing, this means that the battery charger is
charging the batteries.
When the third segment from the left in the battery symbol (51-L) is flashing, this means that the battery charger is finishing the
battery charging cycle.
8.
When all segments of the battery symbol (51-L) are steadily lit, the battery charging cycle is complete.
9.
Disconnect the battery charger plug (6) from the mains and place it in its holder (7).
10. Carefully lower the recovery tank (33).
11. Now the machine is ready to be used.
NOTE
For further information about the operation of the battery charger (5), see the relevant Manual.
11/2014
INSTRUCTIONS FOR USE
9099980000 - SC500
ENGLISH