revised 07/2017
(**) As described in the Use/operation chapter, set the machine and the on-board battery charger on the basis of the type of
battery to be installed by modifying the BAT parameter from the table below:
Installed battery type
WET
GEL / AGM
GEL DISCOVER
GEL OPTIMA
GEL EXIDE
GEL FULLRIVER
Alarms log screen (G, Fig. 9)
This function allows you to check for any stored alarms on the machine.
Use this function only with support from a Advance Service Centre to solve
any operating problems.
To return to the main screen (E, Fig. 8), press push-button (A) repeatedly.
Operating Time Counter Screen (H, Fig. 10)
This function allows you to check the total accumulated hours of work for each
machine subsystem:
TOTAL counter (machine running time)
DRIVE counter (drive system usage time)
BRUSH counter (brush rotation system usage time)
VACUUM counter (vacuum system usage time)
To return to the main screen (E, Fig. 8), press push-button (A).
User Key Management Screen (I, Fig. 11)
This feature allows to determine whether the machine can be used with any
user key (factory setting) or only with one or more specific user keys.
Identification of a specific user key to be used for the machine:
1.
Remove the Supervisor key (if any) from the key reader.
2.
Place the user key in the key reader and press the push-button (A).
Removal of a specific user key from the list of keys to be used for the
machine:
1.
Remove the Supervisor key (if any) from the key reader.
2.
Place the user key in the key reader and press the push-button (B).
Return to factory setting (any user key enabled for the machine):
1.
Remove the Supervisor key (if any) from the key reader.
2.
Press the push-button (B).
3.
Confirm the operation by pressing the push-button (A).
To return to the user mode screen, press push-button (C).
To return to the main screen (E, Fig. 7), press push-button (A).
11/2014
Wet cell batteries
Generic GEL or AGM batteries
GEL batteries or DISCOVER
brand
®
GEL batteries or OPTIMA™ brand
GEL batteries or EXIDE
/SONNENSHINE brand
®
GEL batteries or FULLRIVER
®
INSTRUCTIONS FOR USE
brand
9099980000 - SC500
Value
0
1
2
3
4
5
G
Figure 9
H
Figure 10
I
Figure 11