Nordcap GEKO 800 Mode D'emploi page 59

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

PAR
DESCRIPTION
digital outputs
Operation controlled by fourth output
0 = CELL LIGHT
the auxiliary key and paramaters i0 and u2 will be activated
1 = DEMISTER RESISTORS
the auxiliary key and paramaters u6 will be activated
2 = AUXILIARY OUTPUTS
u1
the auxiliary key and paramaters i5 and u2 will be activated
3 = ALARM OUTPUTS
the parameter u4 will be activated
4 = DOOR RESISTORS
the parameter u5 will be activated
5 = EVAPORATOR VALVE
the parameter u7 and u8 will be activated
Enabling of manual switch on/off of the cell light or the auxiliary output when the instrument
u2
is switched off (only if u1=0 or 2)
1 = YES
Enabling of alrm output diactivation with the silencing of the buzzer (only if u1=3)
u4
1 = YES
u5
Cell temperature below that at which the door resistors are switched on (only if u1=4)
u6
Operating time of demistor resistors (only if u1=1)
Cell temperature below that at which the evaporator valve is disactivated (relating to
u7
Setpoint + u7) (only if u1=5)
Tipe of evaporator valve contact (only if u1=5)
u8
0 = normally open (active input - closed contact)
1 = normally closed (active input - open contact)
Enabling of buzzer
u9
1 = YES
Operation controlled by K1 relay
0 = no unit
1 = compressor
uA
2 = defrosting
(22)
3 = ventilatore evaporatore
4 = fourth output (see also u1)
Operation controlled by K12 relay
0 = no unit
1 = compressor
ub
2 = defrosting
(22)
3 = evaporator fan
4 = fourth output (see also u1)
Operation controlled by K3 relay
0 = no unit
1 = compressor
uC
2 = defrosting
(22)
3 = evaporator fan
4 = fourth output (see also u1)
Operation controlled by K4 relay
0 = no unit
1 = compressor
ud
2 = defrosting
(22)
3 = evaporator fan
4 = fourth output (see also u1)
energy saving in real time
HE1
Time of activation of the Energy Saving function in real time (see also r4 and HE2)
Duration of the Energy Sav. function in real time (see also r4 and HE1)
HE2
00:00 = the ES function in real time will not be activated
defrosting in real time
Time of activation of first defrosting period in real time (only if d8=3)
Hd1
--:-- = the first defrosting in real time will not be activated
Time of activation of second defrosting period in real time(only if d8=3)
Hd2
--:-- = the second defrosting in real time will not be activated
Time of activation of third defrosting period in real time (only if d8=3)
Hd3
--:-- = the third defrosting in real time will not be activated
Time of activation of fourth defrosting period in real time (only if d8=3)
Hd4
--:-- = the fourth defrosting in real time will not be activated
Time of activation of fifth defrosting period in real time (only if d8=3)
Hd5
--:-- = the fifth defrosting in real time will not be activated
Time of activation of sixth defrosting period in real time (only if d8=3)
Hd6
--:-- = the sixth defrosting in real time will not be activated
(21)
(6)
(20)
(20)
(20)
(20)
MIN
MAX
0
6
0
1
0
1
-99.0
99.0
(6)
1
120
0.0
99.0
0
1
0
1
0
4
0
4
0
4
0
4
00:00
23:59
00:00
23:59
00:00
23:59
00:00
23:59
00:00
23:59
00:00
23:59
00:00
23:59
00:00
23:59
GB - 59
MU
TN
BT
°C
+2 / +8
-20 / -15
flag
0
0
flag
...
...
flag
...
...
°C
...
...
min
...
...
°C
...
...
flag
...
...
flag
...
...
flag
...
...
flag
...
...
flag
...
...
flag
...
...
h:min
...
...
h:min
...
...
h:min
...
...
h:min
...
...
h:min
...
...
h:min
...
...
h:min
...
...
h:min