 Before use, check that the device is free from damage or signs that may indicate an er-
ror/defect/failure. If in doubt, do not install or use the heater, but return it to the supplier!
 This heater has been designed to be hung horizontally from a wall; therefore do not use it whilst
it is standing, lying or in any other way!
 Carefully choose the place where you wish to attach the heater to the wall. Make sure that the
base is firm, flat and non-combustible. Do not position the heater just below or above a socket
or close to heat sources such as cooking rings, etc.
The heater has to hang at least 180 cm above the floor and at least 50 cm below the ceiling.
Should you wish, at any time, to direct the radiation upwards, the distance to the ceiling has to
be 100 cm, certainly when there is a plastic or combustible ceiling. Maintain a distance of at
least 50 cm from side walls. Do not position the heater behind a door!
 The insulation of the heater is IP24 rated (splash proof) and therefore suitable for use in bath-
rooms. A distance of at least 1 m has to be maintained between the heater and baths, taps,
fountains, showers etc. Make sure that no jets of water can be directed at the heater and that
the heater cannot fall into the water.
 Only connect the heater to an earthed socket!
Permanent mounting:
The QH1203 is designed for installation in a permanent position and direct connection to the elec-
tricity network. For safety reasons, this installation should be fitted by an approved electrician.
Plug connection:
The QH1203 can also be connected directly to a power socket using the electric cable and plug.
Make sure that the electric cable does not hang over any (sharp) edges, does not make any sharp
angles, cannot be dragged and does not touch any hot surfaces.
Important: the electric cable and plug form a whole. Therefore, if either the electric cable or plug is
damaged they should both be replaced by an electrician. Only mount the original parts!
 When positioning and connecting the heater, make sure that your hands do not touch the heat-
ing elements. This is because traces can be left behind which, afterwards, will have a negative
effect on the radiated heat.
 For use with a plug, the following applies: do not use extension leads and do not connect any
other equipment next to the heater in the same socket!
Position the mounting bracket with the long side and 2 holes against the wall in the required
position, then mark the drill holes. Make sure that the drill holes are positioned at the same
height! Remove the bracket and drill 2 holes in the spots marked. Knock in the raw plugs, posi-
tion the bracket over the top and screw it firmly into the wall using the screws supplied.
 Place the heater over the bracket with the cord down and large holes positioned over large
holes. Screw securely using the bolts, rings and nuts supplied (1).
 Turn the heater to the required position. The body of
the heater can be turned to 5 positions (Small heater
holes over small bracket holes (3)). The mid position is
horizontal to the room. The two positions which are di-
rected upwards will only be used in exceptional cases
and require a greater distance to the ceiling (1 metre).
Finally, the heater has two positions which are directed
downwards. These are the standard positions. Secure
the heater at the required angle by screwing both of
the small screws (2) into the double holes.
 The heater is now ready for use.
The QH1203 is supplied with a knob, ring and spring washer that is intended for a special model.
These parts are surplus and not intended for your model.