HYDAC ELECTRONIC EDS 4000 Notice D'utilisation page 23

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

EDS 4000 programmable
Vibration resistance to
DIN EN 60068-2-6 at 10 ..500Hz
Shock resistance to
DIN EN 60068-2-29 (1 ms)
Protection class to IEC 60529
Other data:
Supply voltage
For use acc. to UL-specification
Current consumption
Residual ripple of supply voltage
Life expectancy
Weight
Reverse polarity protection of supply voltage, excess voltage, override and short circuit protection are
provided.
FS (Full Scale) = relative to the complete measuring range
1)
-25°C with FPM seal, -40°C on request
2)
Environmental conditions to 1.4.2 UL 61010-1; C22.2 No. 61010-1
Status: 16.06.2015
≤ 20 g
≤ 100 g
IP 67 (M12x1, when an IP67 connector is used)
8 .. 32 V DC
- limited energy - according
9.3 UL 6110; Class 2;
UL 1310/1585; LPS UL 60950
≤ 25 mA with inactive switching outputs
≤ 1,225 A with 1 switching output
≤ 2,025 A with 2 switching outputs
5 %
> 10 million cycles, 0 .. 100 % FS
approx. 145 g
HYDAC ELECTRONIC GMBH
9
E
Part No.: 669737