EDS 4000 programmable
Additional installation suggestions which, from experience, reduce the effect of
electromagnetic interference:
• Make line connections as short as possible
• Use screened cabling (e.g. LIYCY 4 x 0.5 mm²)
• The cable screening must be fitted by qualified personnel subject to the ambient conditions
and with the aim of suppressing interference
• Keep the unit well away from the electrical supply lines of power equipment, as well as from
any electrical or electronic equipment causing interference
5 Pin connectiones
EDS 4XX8-XXXX-X-PX-000-X1
Process connection
Programming connection
M12x1, 5-pole connection
+U
= Voltage supply
B
OUT 2 = Switching output 2
0 V
= Ground
OUT 1 = Switching output 1
CP
= Comport
6 Connection diagram
1
2
3
EDS 4000
4
5
Process connection
Note:
Pin 5 must not be connected during
Normal process operation mode!
Status: 16.06.2015
Pin 1
Pin 2
+U
Out 2
B
+U
B
+U
B
OUT 2
0V
EDS 4000
OUT 1
Connection to HPG 3000
HYDAC ELECTRONIC GMBH
Pin 3
Pin4
OUT 1
0V
0V
4
3
5
1
2
+Ub
1
1
2
2
0 V
3
3
HPG 3000
4
4
Comport
5
5
5
E
Pin 5
CP
Part No.: 669737