4.12 Connecting an external boiler
Boiler model LUNA HT 1.330 feature a three way power valve for
connecting a second external boiler.
Connect the boiler water pipes as shown in figure.
Remove the resistor from terminals 9-10 of terminal board M2, and
connect the optional DHW priority sensor to them (figure 26).
Insert the sensor's probe in the relevant hole in the boiler.
Set domestic hot water temperature using the control knob 7, figure 1
on the boiler's front panel.
LEGEND
UB:
DHW boiler unit
UR:
central heating unit
V3V:
three way valve
M2:
terminal board
SB:
DHW priority sensor
MR:
central heating delivery
MB:
DHW delivery
RR:
central heating/DHW return
RB:
resistor, to be removed
NOTE: legionella function is active (factory set = ON; see section 9
parameter 555.1).
4.12 Branchement d'un chauffe-eau extérieur
Cette chaudière est conçue pour la connexion d'un ballon extérieur car
elle est équipée à l'origine d'une vanne à trois voies motorisée.
Effectuer le raccordement hydraulique du ballon comme indiqué sur
la figure.
Relier la sonde ctn de priorité sanitaire, fournie comme accessoire, aux
bornes 9-10 du bornier M2 sur la figure 26 après avoir ôté la résistance
électrique présente.
L'élément sensible de la sonde ctn doit être introduit sur le puisard
spécial se trouvant sur le ballon.
Le réglage de la température de l'eau sanitaire et le choix du programme
horaire peuvent être effectués directement sur le panneau de commande
de la chaudière comme décrit dans ce manuel dans les consignes des-
tinées à l'utilisateur.
LEGENDE
UB: ballon
UR: installation de chauffage
V3V: vanne 3 voies
M2: bornier de raccordement
SB: sonde ballon de priorité sanitaire
MR: départ chauffage
MB: départ ballon
RR: retour du chauffage/ballon
NOTA: la fonction anti-légionelles est active (réglage usine = ON; voir
paragraphe 9 paramètre 555.1).
31
Fig. 26