Using the water
The water temperature is
mixed according to the posi-
tion of the pre-selecting mix-
ing tap(s) or premixing valve.
Make sure that the water
pump is switched off when
you have finished using the
water.
Draining the
Truma-Therme
If the mobile home is
not used during peri-
ods of frost, it is essential
that the Truma-Therme be
emptied!
1. Interrupt current for water
pump (main switch or trans-
former).
2. Drain water from tank (or
remove water pump from
tank).
3. Open taps in kitchen and
(or) bathroom and set pre-
mixing valve(s) – if available –
to hot.
4. Turn draining and ventilat-
ing valves (4) to full extent to
open.
6
5. Check whether all the
water content (5 litres) has
completely run out.
There shall be no guaran-
tee claims for damage
caused by frost!
Using the hose clips SC
(5; Part no. 40712-01 –
not included in scope of de-
livery) it is possible to route
the water hoses on the hot
air pipes, providing protec-
tion against frost.
Clamp the hose clips under
the clips of the hot air pipes.
They can also be used for
fastening the water hoses to
the wall or floor.
Maintenance
Use wine vinegar for de-scal-
ing the Therme, this being in-
troduced into the appliance
via the water supply. Allow
the product to react and then
thoroughly flush out with
plenty of clean water. To
sterilise the water we recom-
mend „Certisil-Argento".
Other products, particularly
those containing chlorine, are
not suitable.

Technical data

determined in accordance
with Truma test conditions
Water content: 5 litres
Operating pressure:
max. 1.2 bar (only use pump
without non-return valve)
Power supply:
230 V ~, 50 Hz
Power consumption:
300 Watt
Thermal cut-out: 65°C
Over-temperature
protection: 85°C
Heating time from approx.
15°C to approx. 60°C:
approx. 50 minutes
Weight (without contents):
approx. 2 kg complete with
drain and venting valves
Dimensions:
length 37 cm, height 23 cm,
width 22 cm
Conformity Declaration:
The Truma-Therme complies
with the requirements of
EN 60335, EMC directive
89/336/EEC, low voltage di-
rective 73/23/EEC and the as-
sociated standards and tech-
nical specifications, and is
therefore entitled to bear the
CE symbol.
The right to effect technical
modifications is reserved!