Product Description - Dovre Sense 100 Installation Et Mode D'emploi

Masquer les pouces Voir aussi pour Sense 100:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 61
the appendix "Distance from combustible
material".
Remove combustible material such as lino-
leum, carpets/rugs and similar materials below
the fireproof protective plate.
Keep sufficient distance between the appli-
ance and combustible materials such as
wooden walls and furniture.
The connecting tube also radiates heat. Ensure
that there is sufficient distance or a shield
between the connecting tube and combustible
material.
The rule of thumb for a single-walled tube is a
distance of 3x the diameter. If a lining shell is
fitted around the tube, a distance of 1x the dia-
meter is permissible.
Carpets and rugs must be at least 80 cm away
from the fire.
Use a fireproof floor plate to protect a flam-
mable floor from any ash which may fall in front
of the stove. The protective plate must comply
with national standards.
For the dimensions of the fireproof protective
plate: see the appendix "Distance from com-
bustible material".
For further requirements in connection with fire
safety: see the appendix "Distance from com-
bustible material".
8

Product description

5
5
1. Connection collar
2. Door
3. Side glass
4. Latch
5. Air slide
Subject to change because of technical improvements
1
2
3
4
09-20021-009
1
2
3
4
09-20021-010

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Sense 103Sense 200Sense 203

Table des Matières