Troubleshooting - Sub-Zero Icbpro3650 Guide D'utilisation Et D'entretien

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 18
T ROU B L E SH O O T I N G

Troubleshooting

UN IT OP ER AT I O N
No lights or cooling.
Verify power is on.
Verify electrical power to the unit and home circuit
breaker is on.
No lights in the refrigerator or freezer.
The door/drawer may have been left ajar which has
disabled lights to eliminate excess heat. If the lights are
out, close the door/drawer for one hour. If the lights are
still out, contact Sub-Zero Factory Certified Service.
LED interior lighting must be replaced by Sub-Zero
Factory Certified Service.
Frost, condensation, or ice build up inside the unit.
Verify the condenser is clean.
Verify the door/drawer is closing properly.
Verify the door/drawer has not been left ajar.
Verify the door/drawer gasket does not have rips or
tears. If it does, contact Sub-Zero Factory Certified
Service.
If icing is heavy, turn the unit off and use a handheld
steamer to melt the ice. Do not use a hair dryer. Once
the ice has melted, wipe up any water with a cloth or
paper towel.
|
8
English
High temperatures, the unit runs excessively, or is giving
off too much heat.
Verify the condenser is clean.
Verify the door/drawer is closing properly.
Verify the door/drawer has not been left ajar.
Increased ambient temperatures may cause the com-
pressors to run longer.
If temperature display shows 3°C and -18°C, but is not
cooling, contact Sub-Zero Factory Certified Service.
ODOR
The unit should be cleaned before using for the first time.
This will clear any odors that may have been trapped
during shipping.
Replace the air purification cartridge.
Clean the unit and shelving thoroughly.
Uncovered food could create an odor which may require
cleaning.
Remove and clean the drain pan located behind the
kickplate, and reinstall.
ICE P RO D UC T IO N
No ice.
Verify
or
appears in the freezer external display.
Verify the ice maker has been on for at least 24 hours.
Verify the freezer temperature is near -18°C.
Verify the ice container is properly installed.
Verify the ice maker arm in the down position.
Verify water is being supplied to the unit.
Blue or green ice.
Possible copper supply line corrosion. Contact a
plumber to clean or replace.
Black flecks in the cubes.
Stop use and contact Sub-Zero Factory Certified
Service.
Bad taste.
Defrost the freezer and clean with soap and water.
Place coffee grounds or charcoal briquettes in the
freezer to absorb odor.
Hollow cubes.
Clean the condenser. Contact Sub-Zero Factory Certified
Service if unresolved.
SE RV IC E
Maintain the quality built into your product by contacting
Sub-Zero Factory Certified Service.
When contacting service, you will need the model and
serial number of your unit. Both numbers are listed on
the product rating plate. Refer to page 4 for rating plate
location.
For warranty purposes, you will also need the date
of installation and name of your authorized Sub-Zero
dealer. This information should be recorded on page 2.