3. Make sure the battery charger cable is plugged into an
electrical outlet that will provide voltage and frequency
according to the serial number plate/technical data (D,
Fig. 31).
NOTE
When the battery charger is connected to the
electrical
outlet,
automatically cut off.
The green indicator light (B, Fig. 31) flashes when
the battery charger is charging the batteries.
4. When the green indicator light (B, Fig. 31) stays on, the
battery charging cycle is over.
5. When the battery charging cycle is over, disconnect the
battery charger cable (A, Fig. 31) from the electrical outlet
and wind it around it's housing on the machine.
6. Now the machine is ready to be used.
NOTE
For further information about the operation of the
battery charger (C, Fig. 31), see the relevant Manual.

FUSE CHECK/REPLACEMENT

1. Remove the recovery tank as shown in the Use chapter.
2. Disconnect the battery negative terminal.
3. Remove the screws (A, Fig. 32) and remove the electrical
component box cover (B).
4. Check/replace the fuses:
– Brush fuse (C, Fig. 32): (40 A)
– Vacuum system fuse (D, Fig. 32): (40 A)
– Solenoid valve and electronic board fuse (E, Fig. 32):
(5 A)
5. Reassemble in the reverse order of disassembly.