Fuse Check/Replacement/Reset - Clarke RSW 37 Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

ENGLISH

FUSE CHECK/REPLACEMENT/RESET

1.
Drive the machine on a level ground and engage the parking brake.
2.
Turn the ignition key (72) to "0".
3.
Open the hood (42).
4.
Disconnect the battery connector (46).
Fuse check/replacement
5.
Remove the fuse box cover (49).
6.
Check/replace the relevant fuse among the following (Fig. 23):
F1 fuse (25 A): Main fuse (ignition switch circuit)
F2 fuse (25 A): Filter shaker motor
F3 fuse (40 A): Manual vacuum system (optional)
F4 fuse (10 A): Horn and pivoting light
F5 fuse (10 A): Working light (optional)
F6 fuse (10 A): Side broom motors
F7 fuse (25 A): Spare
F8 fuse (10 A): Spare
Fuse check
7.
Check one of the following fuses (50 and 51) (Fig. 23) for deactivation:
FA main broom/vacuum fan motor circuit breaker (30 A)
FT drive system fuse (30 A)
Reset any deactivated fuse, when the component that caused deactivation has fully cooled down.
8.
Close the hood (42).
22
FA
FT
Figure 23
F1
F2
F3
F4
F5
F6
F7
F8
Operator's Manual - RSW 37
S311293C

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

9084209010

Table des Matières