8.3 Operating data

All current operating statuses are displayed in the "Operating
data" menu item.
You can access the operating data menu by:
pressing the (MENU) button for approximately 5 seconds



































EN-12
select the menu item "operating data" with the arrow
buttons and confirm with the ENTER button (
Depending on the system configuration, the following data can
be queried in the "operating data" menu:
Display of sensor and system values
The outside temperature is used for calculating the return set temperature, for frost
protection functions and for defrosting.
Heat pump off / domestic hot water / heating / swimming pool / cooling / defrost
Displays the measured return temperature of heating circuit 1.
Displays the measured flow temperature. This temperature is used for frost protection
functions and for safeguarding defrosting.
Displays the measured return temperature (R4) during cooling operation.
Displays the measured flow temperature (R11) during cooling operation.
Indicates whether a heating/cooling requirement is present. Even if a request is
pending, it is possible that the heat pump will not operate (e.g. idle times, flushing
periods). This block is shown by the pre-set lock symbol [
Displays the calculated return set temperature
Displays the measured return temperature
Indicates whether a heating request is pending. Even if a request is pending, it is
possible that the heat pump will not operate (e.g. idle times, flushing periods). This
block is shown by the pre-set lock symbol
Displays the calculated return set temperature.
Displays the measured return temperature of heating circuit 1.
Displays the measured flow temperature.
Displays the dew point for heating/cooling circuit 1 calculated from the values for room
climate station 1.
A programmed raise or lowering is integrated into the display.
Displays the room humidity in the room climate station for heating/cooling circuit 1.
Displays the room set temperature.
Displays the room temperature in the room climate station for heating/cooling circuit 1.
Displays the calculated set temperature for heating circuit 2/3.
Displays the minimum possible temperature for silent cooling in heating circuits 2/3,
derived from the calculation of dew point plus dew point distance.
Displays the measured temperature for heating circuit 2/3.
A programmed raise or lowering is integrated into the display.
Display of the measured room humidity when using a room climate station or Smart-
RTC for heating/cooling circuit 2/3.
Displays the room set temperature.
Displays the measured room temperature when using a room climate station or
Smart-RTC for heating/cooling circuit 2/3.
Displays the dew point for heating/cooling circuit 2/3 calculated from the values for
room climate station 2/3.
Indicates which heat generator is available to carry out the heating or cooling request.
1: max. 1 compressor, 2: max. 2 compressors, 3: max. 2 compressors and a 2nd heat
generator