1 General information

For installation, operation and maintenance refer to the
installation and operating instructions. This unit should only be
installed and repaired by a qualified technician. Repairs which
are improperly carried out can endanger the safety of the user. In
compliance with applicable regulations, the installation and
operating instructions must always be available and should be
given to the technician working on the device for his/her
information. We therefore request that these installation and
operating instructions be passed on to the new tenant or owner
should there be a change in occupancy. Do not connect the
device if it is visibly damaged. In this event, ask the supplier for
advice. To prevent damage, ensure only original spare parts are
used. All environmentally-relevant requirements regarding the
recovery, recycling and disposal of materials and components
should be observed in accordance with the applicable standards.
Regulations and safety information
Any adjustments to the settings within the device must only
be carried out by an authorised technician.

2 Heat pump manager

The heat pump manager is essential for the operation of air-to-
water, brine-to-water and water-to-water heat pumps. It
regulates a bivalent, monovalent or mono energy heat pump
heating system and monitors the safety components in the
refrigeration circuit. The heat pump manager is either installed in
the heat pump casing or is delivered with the heat pump as a
wall-mounted controller. It carries out regulation of both the
heating system and the heat source system.
Overview of functions
6 key operating unit
Clear, illuminated LCD with indicators for operating status
and service information
Conforms with utility company requirements
Dynamic menu navigation, customised for the configured
heat pump system
Automatic operating mode switching to auto, summer, or
cooling based on the external temperature.
Remote display interface with identical menu navigation
Return temperature controlled regulation of heating
operation based on external temperature, adjustable fixed-
setpoint or room temperature.
Control of up to three heating circuits
Priority switching
– Cooling first
– Domestic hot water preparation first
– Heating first
– Swimming pool first
EN-2
The heat pump manager should only be operated in dry
rooms with temperatures ranging between 0 °C and 35 °C.
Ensure that no condensation forms on the device.
To ensure that the frost protection function of the heat pump
works properly, the heat pump manager must remain
connected to the power supply and the flow must be
maintained through the heat pump at all times.
Symbols used:
NOTE
Notes contain important information and are indicated in the manual with
the symbol shown above. They are separated from the rest of the text with
horizontal lines above and below.
TIP
Tips contain information for energy-efficient operation and are indicated
in the manual with the symbol shown above. They are separated from the
rest of the text with horizontal lines above and below
Control of a 2nd heat generator
(oil or gas boiler, immersion heater)
Control of a mixer for a 2nd heat generator (oil, gas, solid
fuel boiler, or renewable heat source)
Special program for a 2nd heat generator to ensure
minimum runtimes (oil boiler) or minimum heating times
(main cylinder)
Control of a flange heater for targeted reheating of domestic
hot water with adjustable time programs, and for thermal
disinfection
Output for controlling a circulation pump via impulse or time
program.
Optional control of up to 5 circulating pumps
Defrost management system to minimise the energy
required for defrosting using variable, self-adjusting
defrosting cycle times
Compressor management system to ensure balanced
loading of the compressors for heat pumps with two
compressors
Operating hours counter for compressors, circulating
pumps, 2nd heat generator and flange heater
Keyboard block, child lock
10 alarm memories with date, time and description
Interface for connecting additional communications for LAN,
EIB/KNX, Modbus
Automatic program for targeted heat drying of screed floors
and saving the start and finish times