Wärmepumpenmanager
Button
Standard display (Fig.4.1 on pag. 4)
ESC
Activates or deactivates the keyboard block
Acknowledges a fault
Cancels a change
MODE
Selects the operating mode (see Cap. 5 on pag. 5)
MENU
Jumps to menu
Shifts the heating curve downwards (colder)
Changes the room set temperature or fixed-setpoint
temperature
Selects additional information
Shifts the heating curve upwards (hotter)
Changes the room set temperature or fixed-setpoint
temperature
Selects additional information
Selection for changing the heating curve, room set
temperature or fixed-setpoint temperature
Confirmation of a change
Table 4.2: Operator button functions

5 Operating modes

Six different operating modes can be selected using the (MODE)
button. A time delay occurs while switching the operating mode.
The operating mode can be changed each time the button is
pressed in the order shown below.
COOLING
Selectable only
when the cooling
controller is
connected
SUMMER
WINTER
VACATION
(lower operation)
PARTY
(daytime operation)
2nd heat generat.
(HG 2)
AUTO
L23
The system operates in cooling mode and individual control functions are activated. This operating
mode can only be activated if a cooling controller is connected to the heat pump manager and the
cooling function has been enabled in the preconfiguration.
Only domestic hot water and swimming pool water are heated in the SUMMER mode operation.
Domestic heating is not activated. (Frost protection is ensured.)
The heat pump operates in heating operation. Programmed lowering times, raising times and shut-off
times for heating and domestic hot water heating are activated automatically. Hot water heating,
heating and swimming pool heating are activated according to priority. The heat pump and the 2nd
heat generator are switched on and off are required.
The vacation mode operation lowers the heating characteristic curve and activates the domestic hot
water block. Both functions are independent of any time controls, but the lower values set for these
functions still apply. The duration of the vacation mode operation can be set in the menu "1 settings
– mode – vacation mode". After this time has elapsed, the system switches automatically back to the
previous mode operation.
The programmed lowering of the heating characteristic curves is overridden in the party mode
operation. The duration of the party mode operation can be set in the menu "1 settings – mode –
party mode". After this time has elapsed, the system switches automatically back to the previous
mode operation.
The heat pump is switched off in this mode operation and the entire heat supply is provided by the 2nd
heat generator (HG 2). This is the immersion heater in mono energy systems. In bivalent systems, the
2nd heat generator is the oil or gas heating. Time programs and heating curve settings remain active.
During auto mode operation, an outside temperature-dependent mode operation switching takes place
between the winter - summer - cooling (if possible). The limit temperatures for auto mode operation can
be adapted to individual requirements in the menu settings - mode depending on the outside
temperature.
452115.66.36 · FD 9709
Change of settings (Cap. 8 on pag. 7)
Exits the menu and returns to the main display
Returns from a submenu
Exits a setting without saving changes
Scrolls downwards between menu items on one level
Lowers the value of a setting
Scrolls upwards between menu items on one level
Raises the value of a setting
Selects a setting value in the corresponding menu item.
Exits a setting and saves changes
Jumps to a submenu
NOTE
Heat pump operation block
The heat pump is blocked in the 2nd heat generator operating mode.
Heating operation and domestic hot water preparation in mono energy
systems is carried out using electric heating elements. In the case of
bivalent systems, the 2nd heat generator is used.
English
No action
No action
EN-5