Settings - Dimplex HPL 6S-TUW Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Wärmepumpenmanager

8.2 Settings

All settings which can be changed by the user are made in the
"Settings" menu item.
The following table shows the structure of the "Settings" menu.
The values shown in bold in the setting range represent the
factory default.
The settings menu can be accessed by:
pressing the (MENU) button for approximately 5 seconds
select the menu item "settings" with the arrow buttons and
confirm with the ENTER button (


























L23
).
System-specific parameters
Sets the year, day, month, weekday and time.
The time can be switched between summer and winter time with
the clock change option.
Operating mode settings
Mode operation selection. Changes can be made directly using the
mode button. auto mode can only be selected if the outside
temperature-dependent operating mode switching is activated.
Duration of party mode in hours. After this time has elapsed, the
system switches automatically back to the previous mode
operation. The value for the raise is set in the menu heating circuit
1 – raise.
Duration of vacation mode in days.
After this time has elapsed, the system switches automatically
back to the previous mode operation. The value for lowering is set
in the menu heating circuit 1 – lower.
Sets the desired room set temperature and I ratio when room
temperature control is selected
Settings to lower the heating characteristic curve of heating
circuit 1.
Sets the times at which the lower process for heating circuit
1 should take place.
Sets the temperature value the heating characteristic curve of
heating circuit 1 is to be lowered by during a lower process.
For each weekday, it is possible to select whether time 1, time 2,
no time or both times are active when the temperature is lowered.
Operations to lower the fan speed that exceed a weekday are
activated or deactivated at the end of each day accordingly.
Settings to raise the heating characteristic curve of heating circuit
1.
Sets the times at which the raise process for heating circuit
1 should take place.
Sets the temperature value the heating characteristic curve of
heating circuit 1 is to be raised by during a raise process.
For each weekday, it is possible to select whether time 1, time 2,
no time or both times are active during a raise. Operations to raise
the temperature that exceed a weekday are activated or
deactivated at the end of each day accordingly.
452115.66.36 · FD 9709
NOTE
Dynamic menus
The following describes the complete menu structure. During
commissioning, the control functions and menu structure are adjusted to
the specific system. Non-relevant menu items are then hidden according
to these settings.
Example: Settings for domestic hot water preparation can only be made if
the "Domestic hot water preparation" menu item is configured with "Yes"
in the preconfiguration.
Abbreviations:
HG2 = 2nd heat generator (e.g. boiler)
English
Setting range
13.05.13
MO ... SU
00:00 ... 23:59
yes / no
summer
winter
vacation
party
2nd heat generat.
cooling
auto
0 ...4 hours... 72
0 ...15 days... 150
15.0 ...20.0 °C... 30.0
001 ...060... 999
00:00 ... 23:59
00:00 ... 23:59
0K ... 19
N / T1 / T2 / Y
00:00 ... 23:59
00:00 ... 23:59
0 K ... 19
N / T1 / T2 / Y
EN-9