Page 1
Wärmepumpen- Bedienungsanweisung Manager für den Benutzer Operating instructions for users Manuel d’utilisation à l’usage de l’utilisateur Wärmepumpen- Heat pump Gestionnaire de Manager manager pompe à chaleur Bestell-nr. / Order no. / N°de commande : 452115.66.36 DE / EN / FR · FD 9709 / L23...
Page 3
Einstellung der Sprache Inställning av språket Einstellung Sprache nach einem Neustart Inställningen av språket är möjligt efter en nystart av värmepumphantera- Wärmepumpenmanagers oder im Menü Einstellungen möglich. ren eller i menyn Inställningar. MENUE-Taste für einige Sekunden gedrückt halten Håll MENUE- knappen nedtryckt några sekunder.
Page 4
Instelling van de taal Stille inn språket De taal kan worden ingesteld na een nieuwe start van de warmtepomp- Man kan innstille språket etter oppstart av varmepumpestyring eller i me- manager of in het menu Instellingen. nyen Innstillinger. Houd de MENUE-toets enkele seconden lang ingedrukt Hold MENUE-tasten inne i noen sekunder.
Deutsch Wärmepumpenmanager 1 Allgemeines Vorschriften und Sicherheitshinweise! Bei der Installation, dem Betrieb und der Wartung ist die Montage- und Gebrauchsanweisung zu beachten. Dieses Gerät Innerhalb des Gerätes dürfen Einstellarbeiten nur von einem darf nur von einem Fachmann installiert und repariert werden. zugelassenen Installateur durchgeführt werden.
Wärmepumpenmanager Deutsch 3 Kurzanweisung 3.1 Auswahl des Betriebsmodus Durch mehrmaliges Drücken der Modustaste gewünschter Betriebsmodus auswählen (Textmeldung). Nach erfolgter Einstellung wird nach einer Wartezeit von 10 Sekunden die Betriebsart umgestellt (Symboländerung in der Anzeige). Kühlen Die Anlage arbeitet im Kühlbetrieb. Sommer Es wird nur Warm- und Schwimmbadwasser erwärmt.
Deutsch Wärmepumpenmanager 4 Bedienung Die Bedienung des Wärmepumpenmanagers erfolgt über 6 Es können 6 unterschiedliche Betriebsarten ausgewählt Drucktasten: Esc, Modus, Menue, . Je nach aktueller werden: ↵ Anzeige (Standard oder Menü) sind diesen Tasten Kühlen, Sommer, Auto, Party, Urlaub, 2. Wärmeerzeuger. unterschiedliche Funktionalitäten zugeordnet.
Wärmepumpenmanager Deutsch Taste Standardanzeige (Abb. 4.1 auf S. 4) Änderung von Einstellung (Kap. 8 auf S. 7) Aktivierung, bzw. Deaktivierung der Tastatursperre Verlassen Menüs und Rücksprung Hauptanzeige Quittierung einer Störung Rücksprung aus einem Untermenü Abbrechen einer Änderung ...
Deutsch Wärmepumpenmanager 6 Anpassung des Heizbetriebes Bei der Inbetriebnahme wird die Heizkennlinie entsprechend den Anhebung vor der Sperrzeit eine zu starke Abkühlung der örtlichen und baulichen Gegebenheiten angepasst. Diese Heizflächen vermieden werden. Heizkennlinie kann mit den Wärmer- / Kälter-Pfeiltasten in der Überlagern sich Anhebung und Absenkung, so hat die Hauptanzeige individuellen...
Wärmepumpenmanager Deutsch 7.3 Zirkulation Im Menüpunkt "Einstellungen - Warmwasser - Zirkulation" TIPP kann die Ansteuerung der Zirkulationspumpe programmiert Eine Zirkulationsleitung ist ein hoher Energiefresser. Um Energiekosten werden. Es können maximal zwei Zeitfenster definiert werden. zu sparen, sollte auf auf eine Zirkulation verzichtet werden. Ist diese Jedem Wochentag können maximal zwei Zirkulationszeiten dennoch unumgänglich, ist es Ratsam die Zeitfenster auf die optimalen zugewiesen werden.
Page 12
Deutsch Wärmepumpenmanager Vorkonfiguration aller Anlagenkomponenten zur Einstellbereich Anzeige dynamischen Menügestaltung Anzeige von Informationen zu einem laufenden Anheizung aktiv Anheizprogramm Welches Anheizprogramm läuft aktuell? Startdatum der Anheizung aktueller Schritt / Anzahl notwendiger Schritte aktueller Zustand des Anheizprogrammes aktuelle Rücklauftemperatur / notwendige Rücklauftemperatur Anzahl aktuell abgelaufener Stunden / Anzahl notwendiger Stunden...
Wärmepumpenmanager Deutsch 8.2 Einstellungen Alle Einstellungen die vom Benutzer geändert werden können HINWEIS sind im Menüpunkt "Einstellungen" zu finden. Dynamische Menüs Im Folgenden wird das komplette Menü beschrieben. Bei der Die Tabelle zeigt die Struktur des Menüs "Einstellungen". Die Inbetriebnahme werden Regelfunktionen und Menüaufbau an die im Einstellbereich fettgedruckten Werte entsprechen dem vorhandene Anlage angepasst.
Page 14
Deutsch Wärmepumpenmanager Anlagenspezifische Parameter Einstellbereich Einstellung der gewünschten Rücklaufsolltemperatur bei 10 … 15 °C … 30 gewählter dynamischer Kühlung. Abhängig von der 10 … 15 °C … 30 Außentemperatur wird der Rücklaufsollwert linear angepasst. Dazu dient eine Kennlinie, die bei zwei bestimmten Betriebspunkten eingestellt wird.
Page 15
Wärmepumpenmanager Deutsch Anlagenspezifische Parameter Einstellbereich Für jeden Wochentag kann separat ausgewählt werden, ob eine N / J Thermische Desinfektion zur eingestellten Startzeit gewünscht wird. Die Zirkulationspumpe wird durch eine Zeitfunktion angesteuert. Einstellung der Zeiten, wann die Zirkulationspumpe angesteuert 00:00 ...
Deutsch Wärmepumpenmanager 8.3 Betriebsdaten Alle aktuellen Betriebszustände werden Menüpunkt Auswählen des Menüpunktes „Betriebsdaten“ mit den „Betriebsdaten“ angezeigt. Pfeiltasten und bestätigen mit der ENTER-Taste ( ↵ Folgende Daten können im Menü „Betriebsdaten“ je nach In das Menü Betriebsdaten gelangt man durch Anlagenkonfiguration abgefragt werden: ...
Page 17
Wärmepumpenmanager Deutsch Anzeige von Fühler und Anlagewerten Gibt an, welche Wärmeerzeuger für die Heiz-bzw. Kühlanforderung eingesetzt werden dürfen. 1: max. 1 Verdichter, 2: max. 2 Verdichter, 3: max. 2 Verdichter und ein 2. Wärmeerzeuger Fühler zur Bestimmung des Abtauendes bei der Heißgasabtauung. ...
Deutsch Wärmepumpenmanager 8.4 Dokumentation Im Menü „Dokumentation“ können die Laufzeiten von In das Menü Dokumentation gelangt man durch Verdichter(n), Umwälzpumpen und weiterer Komponenten der drücken der Taste (MENUE) für ca. 5 Sekunden Wärmepumpen-Heizungsanlage abgefragt werden. auswählen des Menüpunktes „Dokumentation“ mit den Pfeiltasten und bestätigen mit der ENTER-Taste ( ↵...
Page 19
Wärmepumpenmanager Deutsch Anzeige von Laufzeiten und gespeicherten Daten Die abgegebene Wärmemenge der Wärmepumpe wird aufsummiert und angezeigt. Die Wärmemenge kann resetet werden. Die Gesamtwärmemenge kann nicht resetet werden. Anzeige der abgegebenen Wärmemenge der Wärmepumpe in der Betriebsart ...
Deutsch Wärmepumpenmanager 8.5 Netzwerk Ist am Wärmepumpenmanager eine zusätzliche Schnittstelle vorhanden, müssen die Parameter im Menü "Netzwerk" entsprechend angepasst werden. Anpassung der Schnittstelle für die Ferndiagnose Einstellbereich Mit der Einstellung Protokoll wird der Typ der eingebauten Schnittstelle und gleichzeitig das Übertragungsprotokoll MODBUS RTU festgelegt.
Wärmepumpenmanager Deutsch 9 Displayanzeigen Der aktuelle Betriebsstatus der Wärmepumpenanlage lässt sich direkt am LC-Display ablesen. 9.1 Normale Betriebszustände Es werden normale Betriebszustände und solche die durch angezeigt. Anzeigen entsprechenden Forderungen des Energieversorgungsunternehmens (EVU) oder Anlagenkonfiguration und WP-Typ erscheinen am Display. durch Sicherheitsfunktionen der Wärmepumpe bedingt sind, aktuelle Statusmeldung Es steht keine Wärmeanforderung an.
Deutsch Wärmepumpenmanager 9.2 Alarmmeldung Blinkt am Display die ESC-Taste rot, so hat der Regler einen Alarm erkannt. Die Ursache für diesen Alarm wird wechselnd mit der Statusanzeige im Klartext angezeigt. Tritt ein Alarm auf, so ist der örtliche Installateur bzw. der Kundendienst zu informieren.
English Wärmepumpenmanager 1 General information For installation, operation and maintenance refer to the The heat pump manager should only be operated in dry installation and operating instructions. This unit should only be rooms with temperatures ranging between 0 °C and 35 °C. installed and repaired by a qualified technician.
Wärmepumpenmanager English 3 Quick reference instructions 3.1 Selecting the mode operation Select the desired operating mode by repeatedly pressing the MODEbutton (text message). The operating mode will change 10 seconds after altering the setting (symbol changes on the display). cooling The system operates in cooling operation.
English Wärmepumpenmanager 4 Operation The heat pump manager is operated using 6 keys: ESC, 6 different operating modes can be selected: MODE, MENU, . Different functions are assigned to Cooling, Summer, Auto, Party, Vacation, 2nd heat ↵...
Wärmepumpenmanager English Button Standard display (Fig.4.1 on pag. 4) Change of settings (Cap. 8 on pag. 7) Activates or deactivates the keyboard block Exits the menu and returns to the main display Acknowledges a fault Returns from a submenu ...
English Wärmepumpenmanager 6 Adjustment of heating operation During commissioning, the heating characteristic curve is raised before the shut-off time to prevent significant cooling of adjusted to suit the building and local conditions. This heating the heating surfaces. characteristic curve can be adjusted to individual temperature If the raising and lowering operations overlap each other, the requirements using the hotter/colder arrow buttons on the main raising operation has priority.
Wärmepumpenmanager English 8 Menu structure 8.1 Start menu Preconfiguration of all system components for Setting range Display dynamic menu structuring The language for menu navigation can be selected from When switching on the available languages. The 'ENTER' key can be used the voltage, always to select the desired language and the arrow key ↑...
Page 32
English Wärmepumpenmanager Preconfiguration of all system components for Setting range Display dynamic menu structuring Which block is currently active and since when has it block active been active. Which block is currently active and how long will it block active ...
Wärmepumpenmanager English 8.2 Settings All settings which can be changed by the user are made in the NOTE "Settings" menu item. Dynamic menus The following table shows the structure of the "Settings" menu. The following describes the complete menu structure. During The values shown in bold in the setting range represent the commissioning, the control functions and menu structure are adjusted to factory default.
Page 34
English Wärmepumpenmanager System-specific parameters Setting range Sets the desired return set temperature when dynamic cooling is 10 … 15 °C … 30 selected. The return nominal value is adapted linear to the outside 10 … 15 °C … 30 temperature.
Page 35
Wärmepumpenmanager English System-specific parameters Setting range Sets the desired domestic hot water set temperature which is to be 60 °C … 85 reached during thermal disinfection. For each weekday, it is possible to select whether thermal N / Y ...
English Wärmepumpenmanager 8.3 Operating data All current operating statuses are displayed in the "Operating select the menu item "operating data" with the arrow data" menu item. buttons and confirm with the ENTER button ( ↵ Depending on the system configuration, the following data can You can access the operating data menu by: be queried in the "operating data"...
Page 37
Wärmepumpenmanager English Display of sensor and system values Sensor for determining the defrost end with hot gas defrosting. Displays the temperature measured in the tank in bivalent-renewable systems. Displays the temperature measured at the collector sensor and solar cylinder. ...
English Wärmepumpenmanager 8.4 History The "history" menu can be used to query the runtimes of the You can access the history menu by: compressor(s), circulation pumps and further components in the pressing the (MENU) button for approximately 5 seconds heat pump heating system.
Page 39
Wärmepumpenmanager English Display of runtimes and stored data The quantity of thermal energy supplied by the heat pump is totalled and displayed. The quantity of thermal energy can be reset. The total thermal energy cannot be reset. ...
English Wärmepumpenmanager 8.5 Network If an additional interface is available on the heat pump manager, the settings in the "network" menu must be adjusted. Adjusting the interface for remote diagnostics Setting range The protocol setting is used to specify the type of the installed ...
Wärmepumpenmanager English 9 Displays The current operating status of the heat pump system can be read from the LCD. 9.1 Normal operating statuses The display shows both normal operating statuses, and those system configuration and heat pump type are shown on the that are required by utility companies or related to the safety display.
English Wärmepumpenmanager 9.2 Alarm message If the ESC button flashes red on the display, the controller has detected an alarm. The cause of this alarm is shown in the plain text display (alternating with the status display). If an alarm occurs, the local heating technician/after-sales service must be informed.
Page 44
English Wärmepumpenmanager network..................................16 operating data ................................9 operating limit................................17 operating mode ..............................3 outside temperature ..............................12 party mode ................................5 protocol ................................... 16 raise ..................................9 raise value................................9 reheating ................................. 3 return set temperature............................. 12 return temperature ..............................12 room set.temp.
Page 45
Wärmepumpenmanager Français Table des matières 1 Généralités ..............................FR-2 2 Gestionnaire de pompe à chaleur ......................FR-2 3 Instructions succinctes ..........................FR-3 3.1 Sélection du mode de fonctionnement............................FR-3 3.2 Modification des valeurs de réglage ............................FR-3 3.3 Réglages et caractéristiques d'exploitation..........................FR-3 4 Commande ..............................
Français Wärmepumpenmanager 1 Généralités Veuillez tenir compte des instructions de montage et d'utilisation Utiliser le gestionnaire de pompe à chaleur uniquement lors de l'installation, de l'exploitation et de l'entretien. Seule une dans des pièces sèches où règnent des températures personne qualifiée est autorisée à...
Wärmepumpenmanager Français 3 Instructions succinctes 3.1 Sélection du mode de fonctionnement Sélectionner le mode de fonctionnement souhaité (message en clair) en appuyant plusieurs fois sur la touche Mode. Une fois les régla- ges effectués, le mode de fonctionnement change après un temps d’attente de 10 secondes (changement de symbole dans l’affichage). Rafraichissement L’installation travaille en mode rafraîchissement.
Français Wärmepumpenmanager 4 Commande La commande du gestionnaire de pompe à chaleur est Il est possible de choisir 6 modes de fonctionnement réalisée à partir de 6 touches : Echap, Mode, Menu, différents : ↵ Différentes fonctions sont attribuées à ces touches en rafraîchissement, été, auto,...
Wärmepumpenmanager Français Touche Affichage standard (Fig. 4.1 à la page 4) Modification du réglage (Chap. 8 à la page 7) ECHAP Activation ou désactivation du blocage du clavier Quitter le menu et retourner à l’affichage principal Acquittement d’un défaut ...
Français Wärmepumpenmanager 6 Adaptation du mode chauffage À la mise en service, la courbe caractéristique de chauffage est pour des bâtiments mal isolés ou augmentée avant le début de adaptée, conformément conditions locales la durée de blocage pour éviter un refroidissement trop important construction.
Wärmepumpenmanager Français 7.3 Circulation Dans le menu « Reglages - Eau chaud.Sanitaire - Circulation », Tuyau il est possible de programmer la commande d'une pompe de Une conduite de circulation est très énergivore. Pour économiser sur les bouclage ECS. Au maximum deux créneaux horaires peuvent coûts énergétiques, il faudrait renoncer à...
Page 52
Français Wärmepumpenmanager Pré-configuration de chacun des composants de l’installation pour permettre une configuration Plage de réglage Affichage dynamique du menu Affichage d’informations sur un programme de chauffe en Mise en chauffe cours active Identification du programme de chauffe en cours de fonctionnement Date de démarrage de la mise en chauffe Étape actuelle/Nombre d’étapes nécessaires...
Wärmepumpenmanager Français 8.2 Réglages Tous les réglages pouvant être modifiés par l'utilisateur se REMARQUE trouvent sous l'option de menu « Reglages ». Menus dynamiques Le menu complet est décrit ci-après. À la mise en service, les fonctions Le tableau présente la structure du menu « Réglages ». Les de régulation et la configuration du menu sont adaptées à...
Page 54
Français Wärmepumpenmanager Paramètres spécifiques à l’installation Plage de réglage Réglage de la valeur consigne de la température retour souhaitée si le 10 … 15 °C … 30 rafraîchissement dynamique est choisi. La valeur consigne de retour 10 … 15 °C … 30 est adaptée de manière linéaire en fonction de la température extérieure.
Page 55
Wärmepumpenmanager Français Paramètres spécifiques à l’installation Plage de réglage Une désinfection thermique implique un réchauffement unique de l’eau chaude sanitaire jusqu’à la température souhaitée. L’état de fonctionnement est arrêté de façon autonome après avoir atteint la température fixée, à minuit ou au plus tard après 4 heures. 00:00 ...
Français Wärmepumpenmanager 8.3 Caractéristiques d’exploitation Tous les états de fonctionnement actuels sont affichés sous en choisissant le menu « Caract. exploit. » avec les l’option « Caract. exploit. ». touches fléchées et en confirmant avec la touche ENTRÉE ↵ On bascule vers le menu des caractéristiques Les données suivantes peuvent être appelées dans le menu d'exploitation...
Page 57
Wärmepumpenmanager Français Affichage des sondes et des valeurs de l’installation Indique quel générateur de chaleur peut être utilisé pour la demande de chauffage ou de rafraîchissement. 1 : max. 1 compresseur, 2 : max. 2 compresseurs, 3 : max. 2 compresseurs et un 2ème générateur de chaleur ...
Français Wärmepumpenmanager 8.4 Historique Dans le menu « Historique », il est possible de consulter les On bascule au menu « Historique » durées fonctionnement du(es) compresseur(s), en appuyant sur la touche (MENU) pendant 5 secondes circulateurs et des autres composants de l'installation de environ ;...
Page 59
Wärmepumpenmanager Français Affichage des durées de fonctionnement et des données enregistrées La quantité de chaleur fournie par la pompe à chaleur est additionnée et affichée. La quantité de chaleur peut être réinitialisée. La quantité de chaleur totale ne peut pas être réinitialisée. ...
Français Wärmepumpenmanager 8.5 Réseau Lorsqu'une interface supplémentaire est disponible sur le gestionnaire de pompe à chaleur, les paramètres doivent être réajustés dans le menu « Reseau ». Adaptation de l’interface pour le télédiagnostic Plage de réglage Le réglage Protocole permet de définir le type d’interface incorporé et ...
Wärmepumpenmanager Français 9 Affichages L'état actuel de fonctionnement de l'installation par pompe à chaleur est lisible directement sur l'écran à cristaux liquides. 9.1 États de fonctionnement normaux Sont affichés les états de fonctionnement normaux et ceux l'écran que la configuration de l'installation correspondante et le inhérents aux exigences des sociétés d’électricité...
Français Wärmepumpenmanager 9.2 Signal d'alarme Lorsque la touche ECHAP clignote en rouge sur l'écran, le régulateur a reconnu une alarme. La cause de cette alarme est affichée en texte clair et alterne avec l'affichage d'état. Alerter l'installateur local ou le SAV si une alarme survient. L'indication du défaut (affichage), la désignation de la pompe à...
Wärmepumpenmanager Français Répertoire de mots-clés Abaissement ............................... 9 Abaissement de la température ..........................3 Adresse ................................... 16 Alarme..................................15 alarme ..................................18 Année..................................9 Augmentation ..............................6 Blocage ................................... 10 blocage clavier ................................4 Blocage de la production d’eau de piscine......................11 Blocage ECS..............................
Page 65
Wärmepumpenmanager Français 452115.66.36 · FD 9709 FR-21...
Page 66
Français Wärmepumpenmanager FR-22 452115.66.36 · FD 9709...
Page 67
Wärmepumpenmanager Français 452115.66.36 · FD 9709 FR-23...
Page 68
Garantiebedingungen Kundendienstadresse siehe Irrtümer und Änderungen vorbehalten. Montage- und Gebrauchsanweisung Wärmepumpe. Subject to alterations and errors. For the terms of the guarantee and after-sales service Sous réserve d’erreurs et modifications. addresses, please refer to the Installation and Operating Instructions for Heat Pumps. Pour les conditions de garantie et les adresses SAV, se référer aux instructions de montage et d'utilisation de la pompe à...