Wärmepumpenmanager























L23
System-specific parameters
Sets the desired domestic hot water set temperature which is to be
reached during thermal disinfection.
For each weekday, it is possible to select whether thermal
disinfection is desired at the set start time.
The circulation pump is controlled by a timer function.
Sets the times at which the circulation pump is to be activated.
For each weekday, it is possible to select whether time 1, time 2,
no time or both times are active for the circulation pump.
Operations that exceed a weekday are activated or deactivated at
the end of each day accordingly.
Sets the desired swimming pool set temperature.
Sets the desired swimming pool temperature with parallel cooling
operation.
Sets whether the waste heat recovery during cooling is dependent
on the switching status of the thermostat or in continuous
operation.
Sets the time programs for blocking swimming pool water
preparation.
Sets the times for the swimming pool block.
For each weekday, it is possible to select whether time 1, time 2,
no time or both times are active for a block. Blocks that exceed a
weekday are activated or deactivated at the end of each day
accordingly.
Sets the swimming pool set temperature to be maintained even
during a swimming pool block.
Sets the time programs for the prioritisation of swimming pool
water preparation.
Sets the start time for the prioritisation of swimming pool water
preparation.
Sets the desired number of hours of the prioritisation of the
swimming pool water preparation.
For each weekday, it is possible to select whether prioritisation is
desired at the set start time.
The language for menu navigation can be selected from the
available languages. The 'ENTER' key is used to confirm the
selection and the 'ESC' key is used to cancel the selection.
Additional languages are available from the after-sales service via
Smart Key.
452115.66.36 · FD 9709
English
Setting range
60 °C ... 85
N / Y
00:00 ... 23:59
00:00 ... 23:59
N / T1 / T2 / Y
5 ... 25 °C ... 60
5 ... 25 °C ... 60
no / yes
00:00 ... 23:59
00:00 ... 23:59
N / T1 / T2 / Y
0 ... 10 ...DHW set temp.
00:00 ... 23:59
1 hour ... 10
N / Y
EN-11